Sada Medical HA-BD Series Stainless Steel High-Pressure Steam Autoclave – 150L / 200L / 280L | Built-in Drying & Advanced Safety Interlocks
Sada Medical HA-BD Series Stainless Steel High-Pressure Steam Autoclave – 150L / 200L / 280L | Built-in Drying & Advanced Safety Interlocks
Heavy-Duty Sterilization That Puts Safety First
In a busy hospital CSSD, dental clinic, or research lab, steam sterilization is routine—but the risks of pressure equipment are real. The Sada Medical HA-BD Stainless Steel High-Pressure Steam Autoclave is engineered with multiple independent safety layers that protect your staff and your facility at every stage of the cycle. From the door interlock that prevents steam entry until the door is fully sealed, to the automatic pressure-lock that keeps the door closed until the chamber drops below 0.027 MPa, the HA-BD eliminates the kind of operator errors that lead to accidents.
Available in 150L, 200L, and 280L chamber capacities, this horizontal pressure steam sterilizer handles the large loads that central sterile supply departments, veterinary hospitals, and microbiology labs depend on. A built-in drying function, automatic cool-air exhaust, and full stainless steel construction make it a reliable, low-maintenance core piece of your disinfection and sterilization equipment lineup.
If you’ve been looking for a large capacity autoclave with drying that won’t compromise on safety, the HA-BD series is ready for the demands of your daily instrument processing.
Why the HA-BD Is Engineered Differently
-
Multiple Safety Interlocks Protect Your Team
Steam cannot enter the chamber until the door is fully closed and sealed. If the door isn’t properly latched, the pilot light remains off and steam is blocked from the jacket and chamber. Once the internal pressure exceeds 0.027 MPa, the door locks automatically and cannot be opened until the pressure drops to a safe level. If an operator accidentally attempts to open the door during a running cycle, the jacket valve closes immediately and the chamber valve opens to release residual pressure—preventing a dangerous steam burst. -
Built-in Drying Function for Wrapped Goods and Textiles
After the sterilization phase completes, the drying timer (adjustable from 0 to 60 minutes) uses residual chamber heat to dry gowns, dressings, wraps, and porous loads. This keeps your sterile packs dry and ready for storage, reducing the risk of recontamination from moisture. The drying phase runs entirely without steam discharge, keeping your workspace clean and comfortable. -
Automatic Water-Shortage and Overload Protection
If the water level drops too low, the HA-BD automatically switches on the water-shortage pilot light, cuts power to the heating element and the sterilization pilot, sounds a buzzer alarm, and releases steam safely. There’s no risk of a dry-running heater. In addition, an overload and leakage protection system cuts power instantly if excessive current or electrical leakage is detected. This medical steam sterilizer is built to safeguard both the operator and the building’s electrical system. -
Independent Safety Valve for Over-Pressure
Should the temperature controller ever malfunction and internal pressure rise above 0.165 MPa, the mechanical safety valve opens automatically and releases steam to the water line. This redundant mechanical backup operates independently of the electronic control system—a critical feature for hospital sterilization equipment that runs unattended cycles overnight. -
Fully Stainless Steel Structure
The chamber, door, and exterior housing are all constructed from corrosion-resistant stainless steel. There are no painted surfaces to peel after repeated exposure to steam, disinfectants, or humidity. This fully stainless steel steam autoclave is designed to look professional and perform reliably in the busiest environments for years. -
Straightforward, Reliable Control
The HA-BD uses a simple panel with indicator lights that show the current cycle status at a glance. Temperature and sterilization/dry timers are adjustable (40°C–134°C, 0–60 minutes each), and an automatic buzzer signals cycle completion. The system also exhausts cool air at the beginning of each cycle for effective steam penetration—no manual valves required. -
CE & ISO 13485 Certified Quality
Manufactured under Sada Medical’s EN ISO 13485:2016 quality system and carrying the CE mark, the HA-BD meets international medical device safety and performance standards. It’s a hospital autoclave machine you can integrate into your CSSD or clinic with confidence.
Who Uses the HA-BD Horizontal Autoclave?
This large-capacity steam sterilizer is purpose-built for high-volume processing of wrapped and unwrapped instruments, textiles, and media:
- Hospital CSSD Departments & Surgical Centers – wrapped surgical trays, gowns, drapes, rubber goods, and dressings
- Veterinary Hospitals & Animal Research – surgical packs, cages, feeding equipment, and rubber mats
- Dental Clinics & Dental Labs – bulk instrument processing, impression trays, and wrapped handpiece kits
- Microbiology, Life Science & Pharmaceutical Labs – culture media, glassware, liquid reagents, and biohazard waste
- Tattoo & Body Piercing Studios – grip tubes, needle bars, and wrapped jewelry packs
- Funeral Homes & Prosthetics Fabrication – reusable instruments and dressing materials
- Research Institutes & Universities – laboratory consumables, discard cycles, and media preparation
If you’ve been searching for a high capacity horizontal autoclave for hospitals, a stainless steel CSSD sterilizer with drying, or a pressure steam sterilizer for surgical instruments, the HA-BD delivers the safety and capacity your facility requires.
Technical Specifications
| Model | HA-BD150 | HA-BD200 | HA-BD280 |
|---|---|---|---|
| Chamber Volume | 150 Liters | 200 Liters | 280 Liters |
| Chamber Size (Ø × H) | Ø440 × 1000 mm | Ø515 × 1000 mm | Ø600 × 1000 mm |
| Working Pressure | 0.22 MPa | 0.22 MPa | 0.22 MPa |
| Working Temperature | 134°C | 134°C | 134°C |
| Temperature Range | 40 – 134°C adjustable | 40 – 134°C adjustable | 40 – 134°C adjustable |
| Sterilization Time | 0 – 60 minutes adjustable | 0 – 60 minutes adjustable | 0 – 60 minutes adjustable |
| Drying Time | 0 – 60 minutes adjustable | 0 – 60 minutes adjustable | 0 – 60 minutes adjustable |
| Temperature Uniformity | ≤ ±2°C | ≤ ±2°C | ≤ ±2°C |
| Power Supply | 9 kW / AC 380V, 50Hz | 9 kW / AC 380V, 50Hz | 12 kW / AC 380V, 50Hz |
| Overall Dimensions | 1400 × 650 × 1600 mm* | 1400 × 750 × 1700 mm* | 1520 × 910 × 1900 mm* |
| Net Weight | 340 kg* | 350 kg* | 462 kg* |
Approximate dimensions and weights; please confirm with our team when ordering. All models include safety interlock door, water-shortage alarm, over-pressure safety valve, overload protection, drying function, and full stainless steel body.
What’s Included with Your HA-BD Autoclave
- Sada Medical HA-BD horizontal pressure steam sterilizer (select 150L, 200L, or 280L)
- Stainless steel loading baskets or shelves (configuration suited to model)
- Power cable and water connection kit
- Detailed user manual and access to Sada Medical’s online installation and operation video library
After-Sales Support That Keeps You Running
Sada Medical backs every HA-BD sterilizer with a 1-year quality guarantee and a responsive support team. Have a question about installation, cycle settings, or routine maintenance? We reply within 24 hours and offer video or photo instruction to guide you step by step. We’ve supplied steam autoclaves to healthcare providers, labs, and clinics worldwide—and we understand that downtime isn’t an option when your facility relies on a single sterilizer.
📞 Get Your Quote & Expert Support in One Click
Talk directly to our sterilization specialists at Sada Medical Equipment Co., Ltd.
📱 Tel / WhatsApp: +86 18056076519 | 📧 vivian@sadamedical.com | 🌍 sadamedical.com