{"product_id":"sd-jq-low-temperature-formaldehyde-steam-sterilizer-efficient-safe-sterilization-for-heat-sensitive-medical-devices","title":"SD-JQ Low-Temperature Formaldehyde Steam Sterilizer | 120L Effective Volume for Heat‑Sensitive Devices | SADA Medical","description":"\u003cdiv style=\"font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; line-height: 1.5; color: #2c3e4f; max-width: 100%;\"\u003e\n\u003c!-- Overview Section --\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eFor \u003cstrong\u003eoperating rooms, endoscopy units, and CSSD\u003c\/strong\u003e that need a reliable low‑temperature sterilization method for \u003cstrong\u003eheat‑sensitive medical devices\u003c\/strong\u003e, the \u003cstrong\u003eSADA Medical SD‑JQ low‑temperature formaldehyde steam sterilizer\u003c\/strong\u003e offers efficient, safe, and fully automated performance. Using a validated mixture of \u003cstrong\u003e2% formaldehyde, 3% alcohol, and 95% distilled water\u003c\/strong\u003e, this sterilizer operates at \u003cstrong\u003e60°C – 76°C\u003c\/strong\u003e, completing a full cycle in \u003cstrong\u003e2 to 3.5 hours\u003c\/strong\u003e. With an \u003cstrong\u003eeffective chamber volume of ≥120 liters\u003c\/strong\u003e, it easily accommodates delicate instruments such as \u003cstrong\u003eflexible and rigid endoscopes, laparoscopic tools, anesthesia equipment, surgical instruments, and medical textiles\u003c\/strong\u003e. The chamber is constructed from \u003cstrong\u003e5052 corrosion‑resistant aluminum alloy\u003c\/strong\u003e, while pipes are \u003cstrong\u003eSUS304 stainless steel\u003c\/strong\u003e and the outer casing is \u003cstrong\u003eABS high‑strength, fire‑retardant material\u003c\/strong\u003e. The \u003cstrong\u003ecomputer‑controlled automatic operation\u003c\/strong\u003e makes the SD‑JQ easy to use and reliable for daily low‑temperature sterilization in hospitals, clinics, and laboratories.\u003c\/p\u003e\n\u003c!-- Video Embed Placeholder (replace with actual embed code) --\u003e\n\u003cdiv style=\"margin: 30px 0; padding: 20px; background: #fafcfd; border: 2px dashed #2c7da0; border-radius: 20px; text-align: center;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; color: #1e3a5f;\"\u003eProduct Video – SD-JQ Low‑Temperature Formaldehyde Sterilizer in Action\u003c\/h4\u003e\n\u003c!-- PASTE YOUR VIDEO EMBED CODE INSIDE THIS DIV --\u003e\n\u003cdiv style=\"background: #e9edf2; border-radius: 12px; padding: 40px 20px; color: #6c7e8f; font-size: 14px;\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/CJUIK0z0KM8\" title=\"SD-JQ Low-Temperature Formaldehyde Steam Sterilizer–Safe \u0026amp; Fast Sterilization for Medical Equipment\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; margin-top: 12px; color: #2c7da0;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Key Features Grid --\u003e\n\u003cdiv style=\"background: #f1f5f9; border-radius: 16px; padding: 20px; margin: 30px 0;\"\u003e\n\u003ch2 style=\"color: #1e3a5f; margin-top: 0; font-size: 22px; border-left: 4px solid #2c7da0; padding-left: 15px;\"\u003e⚙️ Why Operating Rooms \u0026amp; Endoscopy Units Choose the SD‑JQ\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; margin-top: 15px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🌡️ Low Temperature (60‑76°C)\u003c\/strong\u003e\u003cbr\u003eSafe for heat‑sensitive devices: endoscopes, cameras, cables, and electronic instruments – no thermal damage.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e⚡ Fast Cycles (2‑3.5 hours)\u003c\/strong\u003e\u003cbr\u003eEfficient turnaround for OR and endoscopy suite scheduling – reduces instrument inventory needs.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🤖 Fully Automatic Operation\u003c\/strong\u003e\u003cbr\u003eComputer‑controlled system manages the entire cycle – no manual intervention, consistent results.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔧 Durable Construction\u003c\/strong\u003e\u003cbr\u003e5052 corrosion‑resistant aluminum chamber, SUS304 stainless steel pipes, ABS fire‑retardant casing.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📦 Large Effective Volume (≥120L)\u003c\/strong\u003e\u003cbr\u003eTotal chamber volume ≥150L, effective use ≥120L – accommodates multiple endoscopes and instruments per cycle.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🛡️ Safe \u0026amp; Reliable\u003c\/strong\u003e\u003cbr\u003eMaximum pressure only 5 kPa, electric heating, high‑quality insulating cotton – operator and instrument safety.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Specifications Table --\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 30px 0 10px 0;\"\u003e📋 Technical Specifications – SD‑JQ Low‑Temperature Formaldehyde Sterilizer\u003c\/h2\u003e\n\u003cp\u003eEngineered for safe, repeatable low‑temperature sterilization. The chamber is \u003cstrong\u003e5052 corrosion‑resistant aluminum alloy\u003c\/strong\u003e; all pipes are \u003cstrong\u003eSUS304 stainless steel\u003c\/strong\u003e; outer casing is \u003cstrong\u003eABS high‑strength, fire‑retardant material\u003c\/strong\u003e. Below are the complete specifications.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: white; border-radius: 16px; overflow: hidden; box-shadow: 0 1px 3px rgba(0,0,0,0.1);\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; width: 40%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eSD-JQ Low‑Temperature Formaldehyde Sterilizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eTotal Chamber Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e≥150 Liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eEffective Sterilization Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e≥120 Liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSterilizing Agent\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e2% Formaldehyde + 3% Alcohol + 95% Distilled Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSterilization Time\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e2 – 3.5 hours per cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e60°C – 76°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e≤12 kWh per cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eWater Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e3.95 kg\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eHeating Method\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eElectric Heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e5 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003e5052 Corrosion‑Resistant Aluminum Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOuter Casing Material\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eABS (High‑Strength, Fire Retardant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePipe Material\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eInsulation Material\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eHigh‑Quality Insulating Cotton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eComputer‑controlled, fully automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSafety Features\u003c\/td\u003e\n\u003ctd style=\"padding: 12px;\"\u003eLow pressure operation (max 5kPa), electric heating with insulation, automatic cycle monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef9e6; padding: 12px 18px; border-radius: 12px; margin: 10px 0;\"\u003e\n\u003cp style=\"margin: 4px 0;\"\u003e\u003cstrong\u003e🌟 How Formaldehyde Low‑Temperature Sterilization Works:\u003c\/strong\u003e The sterilizer vaporizes a solution of 2% formaldehyde, 3% alcohol, and 95% distilled water at 60‑76°C. Formaldehyde gas penetrates packaging and lumens, alkylating proteins and nucleic acids of microorganisms – achieving high‑level disinfection and sterilization without heat damage. After the cycle, aeration removes residual gas.\u003cbr\u003e\u003cstrong\u003e🌟 Ideal for:\u003c\/strong\u003e Flexible and rigid endoscopes, laparoscopic instruments, anesthesia equipment, breathing circuits, dental handpieces, and any heat‑sensitive medical device that cannot withstand steam autoclaving.\u003cbr\u003e\u003cstrong\u003e🌟 What's included:\u003c\/strong\u003e Low‑temperature formaldehyde sterilizer unit, chemical agent supply system, stainless steel trays, user manual, and power cord.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications \u0026 Safety --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin: 35px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e🏥 Primary Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Rooms\u003c\/strong\u003e – Surgical instruments, anesthesia equipment, laparoscopic tools\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEndoscopy Rooms\u003c\/strong\u003e – Flexible\/rigid endoscopes, cameras, light cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedical Supply Rooms\u003c\/strong\u003e – Protective clothing, masks, and textiles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVeterinary Clinics\u003c\/strong\u003e – Heat‑sensitive surgical tools\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaboratories \u0026amp; Research Facilities\u003c\/strong\u003e – Precision instruments and labware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical Production\u003c\/strong\u003e – Cleanroom equipment and tool sterilization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e✅ Why Choose the SD‑JQ?\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Sterilization\u003c\/strong\u003e – 2‑3.5 hour cycles, saving valuable time in clinical settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe for Delicate Instruments\u003c\/strong\u003e – Low temperature (60‑76°C) prevents thermal degradation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Automatic\u003c\/strong\u003e – Computer‑controlled, easy to use, consistent results\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e – Corrosion‑resistant aluminum + stainless steel + ABS casing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Capacity\u003c\/strong\u003e – ≥120L effective volume, reduces number of cycles per day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Expertise\u003c\/strong\u003e – Trusted by healthcare professionals worldwide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Quality \u0026 Factory Introduction --\u003e\n\u003cdiv style=\"background: #f0f7f4; border-radius: 16px; padding: 20px; margin: 20px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e✅ SADA Medical – Over 12 Years of Sterilization Excellence\u003c\/h3\u003e\n\u003cp\u003eSADA Medical Co., Ltd. has over 12 years of experience in providing high‑quality sterilization solutions. We are a professional manufacturer and supplier of \u003cstrong\u003elow‑temperature sterilizers (formaldehyde, peroxyacetic acid, hydrogen peroxide plasma), steam autoclaves, and ethylene oxide sterilizers\u003c\/strong\u003e, exporting to over 80 countries worldwide. Certified under \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eEN ISO 13485:2016\u003c\/strong\u003e (Medical Devices). The SD‑JQ low‑temperature formaldehyde sterilizer is factory‑tested and ready for daily clinical use. Each unit comes with a \u003cstrong\u003e12‑month warranty\u003c\/strong\u003e and \u003cstrong\u003e24‑hour technical support\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy customers trust SADA Medical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin-top: 5px;\"\u003e\n\u003cli\u003eFactory‑direct pricing – no middleman markup\u003c\/li\u003e\n\u003cli\u003eOEM\/private labeling available for volume orders\u003c\/li\u003e\n\u003cli\u003e12‑month warranty + 24\/7 technical support\u003c\/li\u003e\n\u003cli\u003eFast worldwide shipping from Shanghai, Ningbo, Qingdao ports\u003c\/li\u003e\n\u003cli\u003eCustomized sterilization solutions available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e📄 Download the full catalog, user manual, and cycle guide using the blue button below.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- CTA Button Block --\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get a Quote \u0026amp; Free Consultation!\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eReady to upgrade your low‑temperature sterilization process? Talk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003ca style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20SD-JQ%20low-temperature%20formaldehyde%20sterilizer\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6c7e8f; margin-top: 20px; text-align: center;\"\u003e✔ HS Code 8419200000 – Low‑temperature sterilizers for medical and laboratory use.\u003cbr\u003e✔ Formaldehyde low‑temperature sterilization – validated for heat‑sensitive devices.\u003cbr\u003e✔ ≥150L total chamber volume, ≥120L effective volume – large capacity.\u003cbr\u003e✔ Automatic computer control – consistent, repeatable cycles.\u003cbr\u003e✔ Durable materials: 5052 aluminum chamber, SUS304 pipes, ABS fire‑retardant casing.\u003cbr\u003e✔ 12‑month warranty, 24‑hour technical support.\u003cbr\u003e✔ Ideal for operating rooms, endoscopy units, and CSSD.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":46488808947878,"sku":null,"price":11536.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Main-04_3__cleanup_1.png?v=1752141340","url":"https:\/\/www.sadamedical.com\/en-hispana\/products\/sd-jq-low-temperature-formaldehyde-steam-sterilizer-efficient-safe-sterilization-for-heat-sensitive-medical-devices","provider":"Sada Medical","version":"1.0","type":"link"}