{"product_id":"horizontal-autoclave-steam-sterilizer-ha-ba","title":"Sada Medical HA-BA Horizontal Cylindrical Steam Sterilizer – 150L \/ 200L \/ 280L | Class N, Digital Display, Printer \u0026 Drying","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReliable High-Volume Sterilization With Advanced Safety, Every Cycle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhen your hospital, laboratory, or pharmaceutical facility processes large loads of surgical instruments, textiles, glassware, or culture media, you need a sterilizer that runs consistently and protects your operators at every step. The\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSada Medical HA-BA Horizontal Cylindrical Pressure Steam Autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecombines a spacious chamber, microprocessor-controlled automation, and multiple independent safety systems into a single dependable unit. Whether you choose the 150L, 200L, or 280L model, you get a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass N steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethat is built to keep your sterilization room running efficiently without demanding constant supervision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe HA-BA’s digital display and computer-controlled cycles take the guesswork out of sterilization: simply load your instruments, select the time and temperature, and press start. A built-in drying phase (0–99 minutes adjustable) ensures that dressings, gowns, and wrapped packs emerge dry, while the integrated printer records every cycle for your infection control documentation. With a 304 stainless steel chamber, a safety interlock door, and automatic over-temperature and over-pressure protection, the HA-BA is designed to be the safe, reliable core of your\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emedical instrument disinfection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eworkflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"ds-markdown-paragraph\"\u003eOverall display of the SADA horizontal sterilizer\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/16EkRrUiclc\" title=\"🖨️ HA-BA Horizontal Steam Autoclave with Drying \u0026amp; Printer | 150L-280L for CSSD \u0026amp; Hospital #shorts\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat Makes the HA-BA a Smarter Sterilization Choice\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFully Automatic Digital Control\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe HA-BA is managed by a microprocessor that automates the entire sterilization cycle: water fill, heating, sterilization, steam exhaust, and drying. The bright digital display shows real-time temperature and remaining time, and touch-type keys make it easy to set parameters from 40°C to 134°C, with sterilization and drying timers adjustable from 0 to 99 minutes. This\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomputer controlled autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereduces the training burden and minimizes operator error.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIntegrated Drying Function\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eUnlike basic sterilizers that leave packs wet, the HA-BA includes a dedicated drying phase. After the sterilization plateau, residual heat dries the load, making it suitable for sterilizing gowns, drapes, dressings, and wrapped surgical packs that must be stored dry. This\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehorizontal autoclave with drying\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis especially valuable in hospital CSSD and surgical centers where wet packs compromise sterility.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e304 Stainless Steel Chamber \u0026amp; Robust Build\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe cylindrical chamber is made of 304 stainless steel, resistant to corrosion from repeated steam exposure and disinfection cleaning. Combined with a sturdy outer structure, this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehorizontal pressure steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built to withstand the demands of a busy sterilization department for years.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Interlock Door You Can Trust\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe door cannot be opened until the chamber pressure drops to or below 0.027 MPa, preventing accidental steam release. Likewise, the cycle will not start if the door isn’t properly sealed. This mechanical and electronic interlock system is essential for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh pressure sterilizer safety\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, protecting operators and ensuring every cycle runs under correct conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti-Layer Over-Pressure \u0026amp; Over-Temperature Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIf the internal pressure exceeds 0.24 MPa, the safety valve opens automatically and vents steam to the water link. If the temperature controller malfunctions, independent over-temperature protection cuts the heater. Should the machine run low on water, the power cuts off automatically, the water supply is shut, and an alarm sounds. There’s also heater protection, anti-dry heating, and electric safety protective devices—seven independent safety layers in total.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eBuilt-in Printer for Effortless Traceability\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eEvery cycle is documented automatically: date, time, temperature, and pressure are printed on the integrated thermal printer. For hospital CSSDs, dental clinics, and pharmaceutical labs that must demonstrate\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esterilization monitoring and infection control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecompliance, this eliminates manual logs and creates a reliable paper trail.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePrecise Temperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe HA-BA maintains temperature distribution within ≤ ±1°C across the chamber, critical for effective sterilization of porous loads, liquid media, and hollow instruments. This level of uniformity is a hallmark of a properly engineered\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elaboratory sterilizer and medical autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCE \u0026amp; ISO 13485 Certified\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eManufactured under Sada Medical’s\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEN ISO 13485:2016\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003equality management system and CE marked, the HA-BA meets international medical device standards for safety and performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWho Uses the HA-BA Horizontal Autoclave?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge capacity steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis right at home in any facility that processes substantial loads of wrapped or unwrapped instruments and materials:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHospital CSSD \u0026amp; Surgical Centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– wrapped trays, gowns, drapes, rubber goods, and dressings\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDental Clinics \u0026amp; Dental Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– bulk instrument processing, impression trays, and wrapped handpiece sets\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePharmaceutical \u0026amp; Biotech Facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– glassware, liquid media, and cleanroom garments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVeterinary Hospitals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– surgical packs, animal care tools, and rubber mats\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMicrobiology \u0026amp; Research Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– culture media, test tubes, Petri dishes, and bio-waste\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eTattoo \u0026amp; Piercing Studios\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– bulk sterilization of tubes, grips, and needle bars\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFuneral Homes \u0026amp; Prosthetics Fabrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reusable instruments and porous materials\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIf you’re searching for a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003ehorizontal autoclave for hospitals\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003eClass N steam sterilizer with printer and drying\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, or a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003elarge CSSD sterilizer with safety interlocks\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, the HA-BA is engineered to meet your daily sterilization demands.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BA150\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BA200\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BA280\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e150 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e200 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e280 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Size (Ø × H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ440 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ515 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ600 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSterilization Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrying Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380V 50Hz (220\/380V, 50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380V 50Hz (220\/380V, 50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 kW \/ AC 380V 50Hz (220\/380V, 50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContact us for exact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContact us for exact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContact us for exact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e*\u003cspan class=\"\"\u003eAll models include digital display, computer control, 304 stainless steel chamber, safety interlock door, drying function, built-in printer, automatic safety valve, water-shortage alarm, and multiple safety protections.\u003c\/span\u003e*\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat’s Included with Your HA-BA Sterilizer\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical HA-BA horizontal cylindrical pressure steam autoclave (choose 150L, 200L, or 280L)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBuilt-in mini printer with starter paper roll\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStainless steel loading trays\/baskets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower cable and water connection kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eComprehensive user manual and access to our online operation video guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eAfter-Sales Support You Can Count On\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical backs every HA-BA sterilizer with a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-month warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand a technical support team that responds within 24 hours. Have a question about cycle programming, safety interlocks, or routine maintenance? We offer video or photo guidance to walk you through any step. With exports to healthcare providers in over 50 countries, we understand that reliable\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautoclave sterilization support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis just as important as the machine itself.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get Your Quote \u0026amp; Expert Support in One Click\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eTalk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp 按钮 --\u003e \u003ca href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BA%20horizontal%20steam%20autoclave\" style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- 官网详细询盘按钮 --\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/contact\" style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- 产品目录下载按钮 --\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"HA-BA150","offer_id":40222699258022,"sku":"","price":4663.94,"currency_code":"USD","in_stock":true},{"title":"HA-BA200","offer_id":57473796636838,"sku":null,"price":5441.26,"currency_code":"USD","in_stock":true},{"title":"HA-BA280","offer_id":57473796669606,"sku":null,"price":6443.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Main-06_28cb4277-a6b3-4065-8092-dd2923d3de3a.jpg?v=1779437474","url":"https:\/\/www.sadamedical.com\/en-hispana\/products\/horizontal-autoclave-steam-sterilizer-ha-ba","provider":"Sada Medical","version":"1.0","type":"link"}