{"product_id":"lcd-diaplay-table-top-pulse-vacuum-steam-autoclave-ts-ddv-class-b","title":"Sada Medical TS-DDV LCD Class B Table Top Pulse Vacuum Steam Autoclave – 12L \/ 18L \/ 24L | High-Performance Sterilizer for Clinics, Dental Practices \u0026 Labs","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass B Precision Sterilization That Fits on Your Countertop\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhen your instruments include hollow lumens, porous loads, or delicate packaged tools, ordinary autoclaves cannot guarantee complete sterility. The\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSada Medical TS-DDV Class B Pulse Vacuum Steam Autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eremoves trapped air with multiple pre-vacuum pulses, then follows with a powerful post-sterilization vacuum drying phase. The result? A\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emedical instrument sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethat meets the most rigorous standards for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edental sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003euse, surgical clinics, microbiology labs, and any setting where\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfection control and disinfection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecannot be compromised.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAvailable in\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12L, 18L, and 24L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecapacities, this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etable top autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003egives you a true Class B solution without taking up precious floor space. Its independent steam generator, backlit LCD panel, and intuitive touch-key controls make daily operation fast and error-free.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhy the TS-DDV Belongs in Your Sterilization Room\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTrue Class B Pulse Vacuum Cycles\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThree pre-vacuum stages and a powerful post-vacuum drying phase remove air from even the most challenging loads. The vacuum system pulls down to\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e-0.8 bar\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, enabling full steam penetration into hollow instruments, porous materials, and multi-aperture tools. After the cycle, instruments come out truly dry—residual humidity stays well below 0.2%, so you can store wrapped packs immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClear LCD Display \u0026amp; Touch Controls\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eMonitor cycle stage, chamber temperature, and pressure at a glance on the bright LCD screen. Sealed membrane touch keys are easy to clean and disinfect, and the straightforward interface reduces training time for new staff.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBuilt-in Mini Printer for Documentation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eEvery cycle’s date, time, temperature, and pressure are printed automatically. If your clinic or lab follows\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfection prevention and control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eaudit trails, this data log helps you demonstrate compliance without keeping handwritten notes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBowie \u0026amp; Dick Test \u0026amp; Vacuum Test Included\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eRun the built-in Bowie \u0026amp; Dick test to verify steam penetration and proper air removal. The vacuum test cycle confirms the integrity of the chamber seals—both critical for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCSSD sterilization equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edaily checks and weekly QA routines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFast \u0026amp; Reliable Steam Generation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eAn independent steam generator heats water rapidly, cutting down the total cycle time. The chamber temperature is adjustable from\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e105°C to 134°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with sterilization time programmable from 0 to 99 minutes, giving you flexibility for unwrapped instruments, liquids, rubber goods, and wrapped surgical packs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAdvanced Pathogen Inactivation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe TS-DDV inactivates viruses including HIV, HBV, and the prions associated with mad cow disease, providing an extra safety layer for sensitive clinical and laboratory environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti-Layer Safety Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eOver-pressure and over-temperature protection, a safety valve, and an alarm system work together to protect the operator and the load. The door is secured during the cycle and cannot be opened while the chamber is pressurized.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFully Certified \u0026amp; Globally Trusted\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eManufactured under our\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEN ISO 13485:2016\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003equality management system and CE marked, the TS-DDV is trusted by healthcare professionals in over 50 countries. When you choose this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass B vacuum sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, you’re choosing a device built and tested to medical device standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eClick to watch how to operate the sterilizer and disinfect and sterilize the used medical devices\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/b8Vle9zUKE4\" title=\"TS-DDV Autoclave Operation Guide | Class B Table Top Steam Sterilizer for Clinics \u0026amp; Labs\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWho Relies on the TS-DDV Class B Autoclave?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epulse vacuum steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis designed for professionals who process critical and semi-critical instruments daily:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDental Clinics \u0026amp; Dental Laboratories\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– handpieces, turbines, forceps, and impression trays\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMedical Clinics \u0026amp; Minor Surgery Rooms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– scissors, forceps, speculums, and dressing packs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMicrobiology, Life Science \u0026amp; Research Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– culture media, glass pipettes, test tubes, and bio-hazard waste\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eTattoo, Piercing \u0026amp; Aesthetics Studios\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– needle tubes, grips, tweezers, and jewelry\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVeterinary Practices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– surgical instruments, dental probes, and catheters\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSmall Hospital CSSD Departments\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– backup or satellite sterilization for wrapped trays\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIf you’ve been searching for a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003eClass B autoclave with printer\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003ecompact vacuum sterilizer for dental clinics\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, or a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003etable top steam sterilizer for wrapped instruments\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, the TS-DDV is ready to meet your daily workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable style=\"width: 99.9589%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 26.5563%;\"\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eTS-DDV12\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eTS-DDV18\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eTS-DDV24\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e12 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e18 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e24 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSterilization Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e105°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e105°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e105°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSterilization Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVacuum Depth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eDown to -0.8 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eDown to -0.8 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eDown to -0.8 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eResidual Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e≤ 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e≤ 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003e≤ 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eLCD with touch keys\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eLCD with touch keys\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eLCD with touch keys\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrinter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eBuilt-in mini printer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eBuilt-in mini printer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eBuilt-in mini printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.5563%;\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eAC 220V, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eAC 220V, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.2078%;\"\u003e\u003cspan class=\"\"\u003eAC 220V, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e*\u003cspan class=\"\"\u003eAll models include 3 pre-vacuum pulses, post-vacuum drying, Bowie \u0026amp; Dick test cycle, vacuum test cycle, safety valve, and over-temp\/over-pressure alarm.\u003c\/span\u003e*\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat You Get with Your Sada Medical TS-DDV Autoclave\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eTS-DDV Class B sterilizer (12L, 18L, or 24L)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBuilt-in mini printer with starter paper roll\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStainless steel tray rack and trays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDrain tube and power cord\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDetailed user manual and access to our online setup and operation video guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eAfter-Sales Support You Can Count On\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eEvery TS-DDV sterilizer is backed by a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1-year quality guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand the dedicated support of the Sada Medical team. Have a question about installation, cycle selection, or daily testing? We respond within 24 hours and often provide real-time video guidance to get you up and running faster. From a single unit to clinic chain orders, we’re here to help.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get Your Quote \u0026amp; Expert Support in One Click\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eTalk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp 按钮 --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20TS-DDV%20Class%20B%20pulse%20vacuum%20autoclave\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- 官网详细询盘按钮 --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/contact\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- 产品目录下载按钮 --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"TS-DDV18","offer_id":40250067550374,"sku":"","price":1595.56,"currency_code":"USD","in_stock":true},{"title":"TS-DDV24","offer_id":57473802076326,"sku":null,"price":1779.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/autoclavesterilizer.jpg?v=1622615345","url":"https:\/\/www.sadamedical.com\/en-eurasia\/products\/lcd-diaplay-table-top-pulse-vacuum-steam-autoclave-ts-ddv-class-b","provider":"Sada Medical","version":"1.0","type":"link"}