{"product_id":"eo-sterilization-equipment-cssd-medical-ethylene-oxide-disinfecting-sterilizer","title":"EO Sterilization Equipment for Hospitals and Clinics – SADA-EO Gas Sterilizer","description":"\u003cp data-start=\"185\" data-end=\"352\"\u003e\u003cstrong data-start=\"185\" data-end=\"201\"\u003eModel Number\u003c\/strong\u003e: SADA-EO\u003cbr data-start=\"210\" data-end=\"213\"\u003e\u003cstrong data-start=\"213\" data-end=\"228\"\u003eApplication\u003c\/strong\u003e: Hospital, Cleanroom CSSD, Clinic\u003cbr data-start=\"262\" data-end=\"265\"\u003e\u003cstrong data-start=\"265\" data-end=\"274\"\u003eClass\u003c\/strong\u003e: Class II Medical Device\u003cbr data-start=\"299\" data-end=\"302\"\u003e\u003cstrong data-start=\"302\" data-end=\"324\"\u003eAfter-sale Service\u003c\/strong\u003e: Online technical support\u003c\/p\u003e\n\u003ch4 data-start=\"354\" data-end=\"376\"\u003e\n\u003cstrong data-start=\"359\" data-end=\"375\"\u003eKey Features\u003c\/strong\u003e:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"379\" data-end=\"486\"\u003e\n\u003cstrong data-start=\"379\" data-end=\"403\"\u003eStrong Penetrability\u003c\/strong\u003e: Effectively sterilizes long-tube objects, thin cavities, and complex instruments.\u003c\/li\u003e\n\u003cli data-start=\"489\" data-end=\"589\"\u003e\n\u003cstrong data-start=\"489\" data-end=\"510\"\u003eAdvanced Material\u003c\/strong\u003e: Chamber made from 304 anti-corrosion stainless steel for enhanced durability.\u003c\/li\u003e\n\u003cli data-start=\"592\" data-end=\"681\"\u003e\n\u003cstrong data-start=\"592\" data-end=\"615\"\u003eCustomizable Volume\u003c\/strong\u003e: Available in 80L, 120L, 220L, and 330L sizes to meet your needs.\u003c\/li\u003e\n\u003cli data-start=\"684\" data-end=\"784\"\u003e\n\u003cstrong data-start=\"684\" data-end=\"720\"\u003eEfficient Residual Gas Treatment\u003c\/strong\u003e: Filter removes particles ≥ 0.2μm with a 99.5% filtration rate.\u003c\/li\u003e\n\u003cli data-start=\"787\" data-end=\"881\"\u003e\n\u003cstrong data-start=\"787\" data-end=\"813\"\u003ePowerful Vacuum System\u003c\/strong\u003e: Uses an oil-free vacuum pump, reaching -60kPa in under 30 minutes.\u003c\/li\u003e\n\u003cli data-start=\"884\" data-end=\"1001\"\u003e\n\u003cstrong data-start=\"884\" data-end=\"904\"\u003eWide Application\u003c\/strong\u003e: Suitable for sterilizing high and low-temperature instruments, including human implant devices.\u003c\/li\u003e\n\u003cli data-start=\"1004\" data-end=\"1079\"\u003e\n\u003cstrong data-start=\"1004\" data-end=\"1021\"\u003eNon-Corrosive\u003c\/strong\u003e: Gentle on your sterilized equipment, ensuring no damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1081\" data-end=\"1084\"\u003e\n\u003ch3 data-start=\"1086\" data-end=\"1113\"\u003e\n\u003cstrong data-start=\"1090\" data-end=\"1112\"\u003eProduct Highlights\u003c\/strong\u003e:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1116\" data-end=\"1237\"\u003e\n\u003cstrong data-start=\"1116\" data-end=\"1138\"\u003eSterilization Door\u003c\/strong\u003e: High-quality 5052 aviation aluminum, with a thickness of ≥15mm and pressure resistance of 200Kpa.\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1344\"\u003e\n\u003cstrong data-start=\"1240\" data-end=\"1269\"\u003eAutomatic Air Replacement\u003c\/strong\u003e: Cycle ventilation 5 times every 15 minutes ensures fresh air circulation.\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1518\"\u003e\n\u003cstrong data-start=\"1347\" data-end=\"1368\"\u003eLCD Touch Display\u003c\/strong\u003e: Shows real-time operating status, temperature, humidity, pressure, sterilization time, residual gas treatment time, and steam generator temperature.\u003c\/li\u003e\n\u003cli data-start=\"1521\" data-end=\"1719\"\u003e\n\u003cstrong data-start=\"1521\" data-end=\"1549\"\u003eMultiple Safety Features\u003c\/strong\u003e: Includes over-voltage protection, over-temperature alarm system, ultra-low pressure alarm, and power-off memory function to ensure no data loss or process interruption.\u003c\/li\u003e\n\u003cli data-start=\"1722\" data-end=\"1831\"\u003e\n\u003cstrong data-start=\"1722\" data-end=\"1740\"\u003eEasy Operation\u003c\/strong\u003e: With user-friendly controls and detailed monitoring for complete sterilization processes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1833\" data-end=\"1836\"\u003e\n\u003ch3 data-start=\"1838\" data-end=\"1861\"\u003e\n\u003cstrong data-start=\"1842\" data-end=\"1860\"\u003eSpecifications\u003c\/strong\u003e:\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1862\" data-end=\"2452\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1862\" data-end=\"1958\"\u003e\n\u003ctr data-start=\"1862\" data-end=\"1958\"\u003e\n\u003cth data-start=\"1862\" data-end=\"1874\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1864\" data-end=\"1873\"\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1874\" data-end=\"1887\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1876\" data-end=\"1886\"\u003eVolume\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1887\" data-end=\"1911\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1889\" data-end=\"1910\"\u003eChamber Size (mm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1911\" data-end=\"1932\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1913\" data-end=\"1931\"\u003eUnit Size (mm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1932\" data-end=\"1944\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1934\" data-end=\"1943\"\u003ePower\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1944\" data-end=\"1958\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1946\" data-end=\"1956\"\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2057\" data-end=\"2452\"\u003e\n\u003ctr data-start=\"2057\" data-end=\"2155\"\u003e\n\u003ctd data-start=\"2057\" data-end=\"2069\" data-col-size=\"sm\"\u003eSD-EO80\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2069\" data-end=\"2082\"\u003e80L\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2082\" data-end=\"2106\"\u003e585\u003cem data-start=\"2087\" data-end=\"2092\"\u003e275\u003c\/em\u003e422\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2106\" data-end=\"2129\"\u003e795\u003cem data-start=\"2111\" data-end=\"2116\"\u003e615\u003c\/em\u003e1140\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2129\" data-end=\"2141\"\u003e2.6KVA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2141\" data-end=\"2155\"\u003e110KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2156\" data-end=\"2254\"\u003e\n\u003ctd data-start=\"2156\" data-end=\"2168\" data-col-size=\"sm\"\u003eSD-EO120\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2168\" data-end=\"2181\"\u003e120L\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2181\" data-end=\"2205\"\u003e585\u003cem data-start=\"2186\" data-end=\"2191\"\u003e375\u003c\/em\u003e472\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2205\" data-end=\"2228\"\u003e968\u003cem data-start=\"2210\" data-end=\"2215\"\u003e800\u003c\/em\u003e1240\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2228\" data-end=\"2240\"\u003e3.0KVA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2240\" data-end=\"2254\"\u003e147KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2255\" data-end=\"2353\"\u003e\n\u003ctd data-start=\"2255\" data-end=\"2267\" data-col-size=\"sm\"\u003eSD-EO220\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2267\" data-end=\"2280\"\u003e220L\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2280\" data-end=\"2304\"\u003e705\u003cem data-start=\"2285\" data-end=\"2290\"\u003e505\u003c\/em\u003e552\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2304\" data-end=\"2327\"\u003e968\u003cem data-start=\"2309\" data-end=\"2314\"\u003e800\u003c\/em\u003e1340\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2327\" data-end=\"2339\"\u003e3.3KVA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2339\" data-end=\"2353\"\u003e207KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2354\" data-end=\"2452\"\u003e\n\u003ctd data-start=\"2354\" data-end=\"2366\" data-col-size=\"sm\"\u003eSD-EO330\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2366\" data-end=\"2379\"\u003e330L\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2379\" data-end=\"2403\"\u003e760\u003cem data-start=\"2384\" data-end=\"2389\"\u003e545\u003c\/em\u003e682\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2403\" data-end=\"2426\"\u003e968\u003cem data-start=\"2408\" data-end=\"2413\"\u003e800\u003c\/em\u003e1340\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2426\" data-end=\"2438\"\u003e3.6KVA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2438\" data-end=\"2452\"\u003e227KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2454\" data-end=\"2457\"\u003e\n\u003ch3 data-start=\"2459\" data-end=\"2489\"\u003e\n\u003cstrong data-start=\"2463\" data-end=\"2488\"\u003eSterilization Process\u003c\/strong\u003e:\u003c\/h3\u003e\n\u003col\u003e\n\u003cli data-start=\"2493\" data-end=\"2590\"\u003e\n\u003cstrong data-start=\"2493\" data-end=\"2516\"\u003ePurge (Air Removal)\u003c\/strong\u003e: Air is completely removed from the chamber for consistent sterilization.\u003c\/li\u003e\n\u003cli data-start=\"2594\" data-end=\"2698\"\u003e\n\u003cstrong data-start=\"2594\" data-end=\"2616\"\u003eSterilization Hold\u003c\/strong\u003e: Maintains 121°C (250°F) for 15-20 minutes, ensuring total microbial destruction.\u003c\/li\u003e\n\u003cli data-start=\"2702\" data-end=\"2799\"\u003e\n\u003cstrong data-start=\"2702\" data-end=\"2732\"\u003eExhaust (Depressurization)\u003c\/strong\u003e: Gradually releases pressure to avoid accidents like boiling over.\u003c\/li\u003e\n\u003cli data-start=\"2803\" data-end=\"2901\"\u003e\n\u003cstrong data-start=\"2803\" data-end=\"2813\"\u003eDrying\u003c\/strong\u003e: A vacuum system removes all residual moisture, ensuring dry, ready-to-use instruments.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-start=\"2903\" data-end=\"2906\"\u003e\n\u003ch3 data-start=\"2908\" data-end=\"2937\"\u003e\n\u003cstrong data-start=\"2912\" data-end=\"2936\"\u003ePackaging \u0026amp; Delivery\u003c\/strong\u003e:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2940\" data-end=\"3016\"\u003e\n\u003cstrong data-start=\"2940\" data-end=\"2953\"\u003ePackaging\u003c\/strong\u003e: Standard export wooden box packaging to ensure safe delivery.\u003c\/li\u003e\n\u003cli data-start=\"3019\" data-end=\"3145\"\u003e\n\u003cstrong data-start=\"3019\" data-end=\"3036\"\u003eDelivery Time\u003c\/strong\u003e: 15-20 days after order confirmation. Delivery times may vary based on production season and order quantity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3147\" data-end=\"3150\"\u003e\n\u003ch3 data-start=\"3152\" data-end=\"3211\"\u003e\u003cstrong data-start=\"3156\" data-end=\"3211\"\u003eWhy Choose SADA Medical EO Sterilization Equipment?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"3215\" data-end=\"3326\"\u003e\n\u003cstrong data-start=\"3215\" data-end=\"3235\"\u003eHigh Reliability\u003c\/strong\u003e: Designed for hospitals, clinics, and cleanrooms to ensure a safe and sterile environment.\u003c\/li\u003e\n\u003cli data-start=\"3329\" data-end=\"3440\"\u003e\n\u003cstrong data-start=\"3329\" data-end=\"3347\"\u003eCost-Effective\u003c\/strong\u003e: Offers the same high-performance sterilization as other methods at a more affordable price.\u003c\/li\u003e\n\u003cli data-start=\"3443\" data-end=\"3525\"\u003e\n\u003cstrong data-start=\"3443\" data-end=\"3460\"\u003eUser-Friendly\u003c\/strong\u003e: Easy operation with intuitive controls and a clear LCD display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3527\" data-end=\"3530\"\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eISO 9001:2015 Quality Management Systems\u003cbr\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" width=\"480x480\" height=\"480x480\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo of SADA MEDICAL Products:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/GvAhccZxie4\" width=\"480\" height=\"270\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eIf you're interested in our products, please feel free to contact us by\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003cstrong\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":41544868167846,"sku":"","price":10008.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Main-01_1_3aef1283-29bc-4076-b03f-0b09b2bce13f.jpg?v=1765360844","url":"https:\/\/www.sadamedical.com\/en-eurasia\/products\/eo-sterilization-equipment-cssd-medical-ethylene-oxide-disinfecting-sterilizer","provider":"Sada Medical","version":"1.0","type":"link"}