{"title":"Horizontal Autoclave","description":"Sada Horizontal Autoclave Sterilizer, which adopt the gravity exchange to release the cold air from the chamber. It is more effective and reliable for steam sterilization.\u003cbr data-mce-fragment=\"1\"\u003eThe control system automatically adjust the steam inlet and outlet according to the chamber temperature during sterilization.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIt is an ideal sterilization equipment for hospitals, clinics, beauty salon, laboratory and mushroom.\u003cbr data-mce-fragment=\"1\"\u003eHorizontal Autoclave Sterilizer, Please download the Horizontal Autoclave Sterilizer Catalog and then let us know your preferred models, We will back to you more information and Best Price.","products":[{"product_id":"horizontal-cylindrical-steam-autoclave","title":"A-BC Series Horizontal Autoclave – 150L \/ 200L \/ 280L \/ 400L \/ 500L Hospital Waste Material Sterilizer with Drying Function","description":"\u003cdiv style=\"font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; line-height: 1.5; color: #2c3e4f; max-width: 100%;\"\u003e\n\u003c!-- Overview Section --\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eFor \u003cstrong\u003ehospitals, CSSD, waste treatment centers, and laboratories\u003c\/strong\u003e that require a high‑capacity, reliable sterilizer for \u003cstrong\u003emedical waste and reusable instruments\u003c\/strong\u003e, the \u003cstrong\u003eSADA Medical HA-BC series big horizontal autoclave\u003c\/strong\u003e delivers robust performance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eAvailable in \u003cstrong\u003e150L, 200L, 280L, 400L, and 500L chamber capacities\u003c\/strong\u003e, this \u003cstrong\u003ehorizontal pressure steam sterilizer\u003c\/strong\u003e is designed to handle \u003cstrong\u003ehospital waste, surgical instruments, laboratory glassware, culture media, rubber materials, gowns, dressings, and gloves\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eThe \u003cstrong\u003efully automatic control system\u003c\/strong\u003e manages the sterilization process with \u003cstrong\u003edrying function\u003c\/strong\u003e included – ideal for medical dressing drying after sterilization. Built with a \u003cstrong\u003estainless steel chamber\u003c\/strong\u003e, the HA-BC features \u003cstrong\u003eover‑temperature and over‑pressure auto‑protection\u003c\/strong\u003e, a \u003cstrong\u003esafety interlock door\u003c\/strong\u003e (cannot open until chamber pressure drops below 0.027MPa), an \u003cstrong\u003eautomatic safety valve\u003c\/strong\u003e (releases at \u0026gt;0.24MPa), and \u003cstrong\u003elow water cut‑off with alarm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eWhether you need to sterilize infectious waste before disposal or process large volumes of surgical packs, the HA‑BC horizontal autoclave offers safety, efficiency, and compliance.\u003c\/p\u003e\n\u003c!-- Video Embed Placeholder (replace with actual embed code) --\u003e\u003c!-- Key Features Grid --\u003e\u003c!-- Technical Specifications Table --\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 30px 0 10px 0;\"\u003e📋 Technical Specifications – HA‑BC Series (150L – 500L)\u003c\/h2\u003e\n\u003cp\u003eEngineered for high‑volume waste and instrument sterilization. All models feature a \u003cstrong\u003estainless steel chamber\u003c\/strong\u003e, \u003cstrong\u003eautomatic control\u003c\/strong\u003e, and \u003cstrong\u003ebuilt‑in drying\u003c\/strong\u003e. Below are the complete specifications for all five capacities.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: white; border-radius: 16px; overflow: hidden; box-shadow: 0 1px 3px rgba(0,0,0,0.1);\"\u003e\n\u003cthead style=\"background: #1e3a5f; color: white;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BC150\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BC200\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BC280\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BC400\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BC500\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVolume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e150L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e200L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e280L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e400L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e500L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eChamber Size (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eФ440×1000\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eФ515×1000\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eФ600×1000\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eФ700×1100\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eФ700×1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003e0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003e134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003e40°C – 134°C (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSterilization Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003e0 – 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDrying Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003e0 – 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHeat Average\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003e≤ ±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower (kW)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e9kW\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e9kW\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e12kW\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e18kW\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e18kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"5\"\u003eAC 380V \/ 50Hz (three‑phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOverall Dimensions (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1400×600×1300\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1400×670×1650\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1400×770×1780\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1430×880×1830\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1800×900×1820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTransport Dim. (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1550×750×1850\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1560×820×1850\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1680×920×2100\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1600×1050×2100\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1850×1050×2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGross \/ Net Weight (kg)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e320\/240\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e350\/260\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e465\/365\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e530\/420\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e580\/470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef9e6; padding: 12px 18px; border-radius: 12px; margin: 10px 0;\"\u003e\n\u003cp style=\"margin: 4px 0;\"\u003e\u003cstrong\u003e🌟 Designed for Medical Waste \u0026amp; High‑Volume Sterilization:\u003c\/strong\u003e The HA-BC horizontal autoclave is ideal for treating infectious hospital waste before disposal, as well as for sterilizing large instrument sets, textiles, and laboratory waste. The combination of 134°C steam sterilization and built‑in drying ensures waste is rendered safe and dry, ready for further processing or landfill.\u003cbr\u003e\u003cstrong\u003e🌟 Safety First:\u003c\/strong\u003e The door interlock system (cannot open above 0.027MPa) and over‑pressure safety valve (automatic release at \u0026gt;0.24MPa) provide operator protection. Low water cut‑off prevents dry running.\u003cbr\u003e\u003cstrong\u003e🌟 What's included:\u003c\/strong\u003e Horizontal autoclave unit, stainless steel chamber, drying system, automatic control panel, power cord, user manual. Custom tray configurations available upon request.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications Section --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin: 35px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e🏥 Primary Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospital waste treatment\u003c\/strong\u003e – Infectious medical waste, sharps containers (after shredding)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSSD (Central Sterile Supply Department)\u003c\/strong\u003e – High‑volume surgical instruments, dressing packs, gowns\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaboratories\u003c\/strong\u003e – Biohazardous waste, glassware, culture media, animal bedding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical \u0026amp; biotech facilities\u003c\/strong\u003e – Production waste, cleanroom garments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVeterinary clinics \u0026amp; research centers\u003c\/strong\u003e – Animal waste, surgical kits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuneral homes \u0026amp; prosthetics fabrication\u003c\/strong\u003e – Specialized load sterilization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e✅ Why Choose the HA‑BC for Waste Sterilization?\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge capacity\u003c\/strong\u003e – Up to 500L, reduces number of cycles per day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automatic\u003c\/strong\u003e – Minimal staff training, consistent results\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrying function\u003c\/strong\u003e – Waste comes out dry, easier to handle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety interlock door\u003c\/strong\u003e – No accidental opening under pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow water protection\u003c\/strong\u003e – Prevents damage and ensures cycle integrity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel chamber\u003c\/strong\u003e – Long service life, easy to decontaminate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Capacity Quick Guide --\u003e\n\u003cdiv style=\"background: #e8f0fe; border-radius: 16px; padding: 20px; margin: 25px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e📏 Which capacity fits your facility?\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 10px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: white; border-radius: 12px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 24px; font-weight: bold; color: #2c7da0;\"\u003e150L \/ 200L\u003c\/div\u003e\n\u003cp style=\"margin: 8px 0 0 0; font-size: 13px;\"\u003eSmall hospitals, labs, dental clinics\u003cbr\u003eChamber: Ф440×1000 or Ф515×1000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: white; border-radius: 12px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 24px; font-weight: bold; color: #2c7da0;\"\u003e280L\u003c\/div\u003e\n\u003cp style=\"margin: 8px 0 0 0; font-size: 13px;\"\u003eMid‑size hospitals, regional CSSD\u003cbr\u003eChamber: Ф600×1000\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: white; border-radius: 12px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 24px; font-weight: bold; color: #2c7da0;\"\u003e400L \/ 500L\u003c\/div\u003e\n\u003cp style=\"margin: 8px 0 0 0; font-size: 13px;\"\u003eLarge hospitals, central waste treatment\u003cbr\u003eChamber: Ф700×1100 or Ф700×1300\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Quality \u0026 Factory Introduction --\u003e\n\u003cdiv style=\"background: #f0f7f4; border-radius: 16px; padding: 20px; margin: 20px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e✅ SADA Medical – Quality \u0026amp; Certifications\u003c\/h3\u003e\n\u003cp\u003eSADA Medical Co., Ltd. is a professional manufacturer and supplier of \u003cstrong\u003ehorizontal autoclaves, steam sterilizers, low‑temperature plasma sterilizers, and ethylene oxide sterilizers\u003c\/strong\u003e, exporting to over 80 countries worldwide. We are certified under \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eEN ISO 13485:2016\u003c\/strong\u003e (Medical Devices). The HA-BC series \u003cstrong\u003ebig horizontal autoclave\u003c\/strong\u003e is factory‑tested and ready for demanding daily use. Each unit comes with a \u003cstrong\u003e12‑month warranty\u003c\/strong\u003e and \u003cstrong\u003e24‑hour technical support\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy customers trust SADA Medical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin-top: 5px;\"\u003e\n\u003cli\u003eFactory‑direct pricing – no middleman markup\u003c\/li\u003e\n\u003cli\u003eOEM\/private labeling available for volume orders\u003c\/li\u003e\n\u003cli\u003e12‑month warranty + 24\/7 technical support\u003c\/li\u003e\n\u003cli\u003eFast worldwide shipping from Shanghai, Ningbo, Qingdao ports\u003c\/li\u003e\n\u003cli\u003e20‑25 working days production lead time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e📄 Download the full catalog, user manual, and validation guide using the blue button below.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- CTA Button Block --\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Ready to Order the HA‑BC Horizontal Waste Sterilizer?\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eContact us for factory pricing, OEM service, and fast worldwide shipping. Talk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003ca href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BC%20horizontal%20waste%20autoclave\" style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6c7e8f; margin-top: 20px; text-align: center;\"\u003e✔ HS Code 8419200000 – Horizontal steam sterilizers for medical waste and instrument processing.\u003cbr\u003e✔ 5 models from 150L to 500L – match your facility’s volume.\u003cbr\u003e✔ Fully automatic control with built‑in drying – waste and instruments ready for disposal or storage.\u003cbr\u003e✔ Multiple safety features: door interlock, over‑pressure safety valve, low water cut‑off, over‑temp protection.\u003cbr\u003e✔ Stainless steel chamber – durable, corrosion‑resistant.\u003cbr\u003e✔ Wide temperature range (40‑134°C) and sterilization\/drying times (0‑60 min).\u003cbr\u003e✔ 12‑month warranty, 24‑hour technical support.\u003cbr\u003e⚠️ Power requirement: AC 380V 50Hz three‑phase – please confirm your facility’s power supply.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"HA-BC150","offer_id":40190858100902,"sku":"","price":3682.06,"currency_code":"USD","in_stock":true},{"title":"HA-BC200","offer_id":57473783464102,"sku":null,"price":4132.09,"currency_code":"USD","in_stock":true},{"title":"HA-BC280","offer_id":57473783496870,"sku":null,"price":4663.94,"currency_code":"USD","in_stock":true},{"title":"HA-BC400","offer_id":57473783529638,"sku":null,"price":6239.04,"currency_code":"USD","in_stock":true},{"title":"HA-BC500","offer_id":57473783562406,"sku":null,"price":7732.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Main-03_1ad6a898-4085-4d36-a36e-b71894b95d2d.jpg?v=1764749217"},{"product_id":"mushroom-sterilization-sterilizer-autoclave","title":"Mushroom Sterilization Sterilizer Autoclave","description":"\u003cp\u003e\u003cstrong\u003eMushroom Sterilization Sterilizer Autoclave\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel: HA-BVS\u003cbr data-mce-fragment=\"1\"\u003eChamber Volume: 120L- 5000L\u003cbr data-mce-fragment=\"1\"\u003eDesign pressure: 0.245Mpa\u003cbr data-mce-fragment=\"1\"\u003eDesign temperature: 139ºC\u003cbr data-mce-fragment=\"1\"\u003eWork pressure: 0~0.22Mpa\u003cbr data-mce-fragment=\"1\"\u003eMaterial: SUS304 \/ SUS316 \/ SUS316L\u003cbr data-mce-fragment=\"1\"\u003eDoor: Single Door\u003cbr data-mce-fragment=\"1\"\u003eDisplay: Touch Screen\u003cbr data-mce-fragment=\"1\"\u003eControl System: Siemens PLC + HMI + DCS\u003cbr data-mce-fragment=\"1\"\u003eConfiguration: Loading cart, transport cart, tray\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eProduction time: 30 working days\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 8419200000\u003cbr data-mce-fragment=\"1\"\u003eWarranty: 12 months\u003cbr data-mce-fragment=\"1\"\u003eApplication range: Hospital, lab, clinic, pharmaceutical factory, research institutions, etc.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eBrand:Sada Medical\u003cbr data-mce-fragment=\"1\"\u003eProduct Origin:China\u003cbr data-mce-fragment=\"1\"\u003eShipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eLarge Pulse Vacuum Autoclave Machine\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eTechnology Advantage\u003cbr data-mce-fragment=\"1\"\u003e1. Control system: It is integrated by Siemens PLC + HMI + DCS, advanced function for recording, printing and storing.\u003cbr data-mce-fragment=\"1\"\u003e2. Monitoring system: Independent temperature monitoring system.\u003cbr data-mce-fragment=\"1\"\u003e3. Vacuum pump: The steam condenser is fitted in the exhaust\/vacuum line to condense the steam before entering inside the vacuum pump.\u003cbr data-mce-fragment=\"1\"\u003e4. GMP validation port: The GMP validation ports of 16 temperature sensor are used for validation.\u003cbr data-mce-fragment=\"1\"\u003e5. Controller software design: unique real-timely feedback module based on fuzzy control-theoretical, ensuring accurate processing control, guaranteeing the bond, fluctuation and uniformity of temperature thoroughly.\u003cbr data-mce-fragment=\"1\"\u003e6. Man-machine interface software: menu programming, one-key touch operation and all kinds of operation intensive design, with elegant appearance. Full-color real-time dynamic displaying during each running process.\u003cbr data-mce-fragment=\"1\"\u003e7. Fault: Perfect fault information warning and fault self-diagnosis function.\u003cbr data-mce-fragment=\"1\"\u003e8. Door: National patent door interlock device. National patent sealing technology – closed inflatable seal ring with compressed air.\u003cbr data-mce-fragment=\"1\"\u003e9. Pneumatic valve and solenoid valve: high quality, stable performance and a long lifespan.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eSafety Feature\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e1. Mechanical pressure relief safety valve for chamber and jacket\u003cbr data-mce-fragment=\"1\"\u003e2. Over-pressure protective device\u003cbr data-mce-fragment=\"1\"\u003e3. Over-temperature protective device\u003cbr data-mce-fragment=\"1\"\u003e4. Protective measure device of door safety\u003cbr data-mce-fragment=\"1\"\u003e5. Interlock function device\u003c\/p\u003e\n\u003cp\u003eSpecifications:\u003c\/p\u003e\n\u003ctable width=\"1008\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"99\"\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"120\" style=\"font-style: inherit; font-weight: inherit;\"\u003eChamber Size\u003c\/td\u003e\n\u003ctd width=\"185\" style=\"font-style: inherit; font-weight: inherit;\"\u003eSteam Consumption (KG)\u003c\/td\u003e\n\u003ctd width=\"215\" style=\"font-style: inherit; font-weight: inherit;\"\u003eTap Water Consumption (KG)\u003c\/td\u003e\n\u003ctd width=\"69\" style=\"font-style: inherit; font-weight: inherit;\"\u003ePower\u003c\/td\u003e\n\u003ctd width=\"191\" style=\"font-style: inherit; font-weight: inherit;\"\u003eGross Weight\/Net Weight\u003c\/td\u003e\n\u003ctd width=\"129\" style=\"font-style: inherit; font-weight: inherit;\"\u003eOverall Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003eLxWxH(MM)\u003c\/td\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003eLxWxH(MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS250\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e800x600X600\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e18KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e35KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2-2.4KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e900KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1100x1350X1900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS360\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1000x600X600\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e25KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e40KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2-2.4KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1000KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1300x1350X1900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS600\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1200x610X910\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e30KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e45KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e3-3.6KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1400KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1500x1360X1950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS800\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1500x610X910\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e40KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e50KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e3KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1600KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1800x1360X1950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS1200\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1450x680X1180\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e48KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e55KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e4KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1800KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1750x1440X1950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS1500\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1850x680X1180\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e55KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e60KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e4KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2000KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2150x1440X1950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS2000\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1600x900X1400\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e65KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e65KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e4.5KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2500KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1950x1750X2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS2500\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1950x900X1400\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e75KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e75KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e6KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e3000KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2300x1750X2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eHA-BVS3000\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2400x900X1400\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e90KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e90KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e8KW\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e3500KG\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2700x1750X2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/U3H9KRkdgrA\" width=\"480\" height=\"270\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan data-mce-fragment=\"1\"\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eIf you're interested in our products, please feel free to contact us by\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003cstrong\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -93px; top: -19px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40197187010726,"sku":"","price":9035.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/MushroomSterilizationSterilizerAutoclave1.jpg?v=1622430644"},{"product_id":"pass-through-double-door-high-pressure-steam-sterilizer","title":"Pass Through Double Door High Pressure Steam Sterilizer","description":"\u003cstrong\u003ePass Through Double Door High Pressure Steam Sterilizer\u003c\/strong\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003eIntroduction\u003cbr data-mce-fragment=\"1\"\u003eThe traditional herb powder sterilizer adopts cobalt 60, ethylene oxide, alcohol stifling, microwave, ozone and etc. While these ways cannot ensure drug properties, residual would remain, and the cost would be high. Compared to these traditional ways of sterilization, tests have manifest that steam sterilization is the best way to sterilize herb medicine powder, seasonings and other powder products.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIn terms of shape, this series sterilizer is horizontal rectangular, heated both inside and outside by steam, by this mean, the chamber size could be fully used. The equipped special damp-proof device, with specialized drying craft can eliminate powder packing that formed by using traditional sterilization technology.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eApplication\u003cbr data-mce-fragment=\"1\"\u003eThis series of sterilizer is mainly used for the herb medicine powder, seasonings and some other powder products.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003ePipe System\u003cbr data-mce-fragment=\"1\"\u003eCalorie-hoop interlinkage fast joint not only solve the resorted of the convention threaded fittings, but also convenient for dismount and part changing, cleaning. The normal steam comes from jacket into chamber\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe filters for steam pipe, air filling pipe and vacuum pipe are from PALL company. The performance is excellent with no medium break or contamination unload. That can be repeated clean and repeated flush.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eControl valves\u003cbr data-mce-fragment=\"1\"\u003eThe valves are produced by GEMU Company, Germany. The pneumatic water proof hammer angle valve is fixed in cooling water system that the system can work more smoothly. Other valves are heat resistance angle pneumatic valve which are special for steam (180℃). They are bid directional self-adjustable airproof , big flux with 6 million times working life.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eControl System\u003cbr data-mce-fragment=\"1\"\u003eThe control system incorporated with: PLC + HMI+ Printer + Data logger.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e1, When automatic controller in the failure of the circumstances, the security device makes the sterilization indoor pressure safety in the pressure of the atmosphere to the back of the state, and allow the loading door can be opened.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e2, In order to maintenance, test and emergency needs, manual operation can be through the use of access control tools to complete.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e3, The master controller system:3 level password.The adminstrator can set the user(engineer and operator) name and password.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e4, Touch screen: display work process parameters and sterilization cycle state, the operation is convenient.The engineer can modify the parameters,including the temperature,time,program name,vacuumize times,etc.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003ctable width=\"493\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"220\" style=\"font-style: inherit; font-weight: inherit;\"\u003eItem\u003c\/td\u003e\n\u003ctd width=\"273\" style=\"font-style: inherit; font-weight: inherit;\"\u003eModel: PA-0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eChamber size(L*W*H)\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1050*680*550mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eOverall size(L*W*H)\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e1245*1300*1880mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eWorking temperature\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e105~134℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eDesign pressure\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e0.245Mpa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eWork pressure\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e0.22Mpa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eChamber material\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eThickness: 8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003eMaterial: SUS304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eTemperature equilibrium\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e≤±1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003ePT100 Temperature sensor\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e2 pcs:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003e1sensor movable inside the chamber,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003e1 sensor fixed at the drain port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eTime set\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003e0~999min, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eElectricity supply\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eElectric power: 380V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003eControl Power: 4kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003ePure steam ( generate steam)\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003ePipe diameter: DN25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esupply(0.4~0.6Mpa)\u003c\/td\u003e\n\u003ctd\u003e20 kg\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eTap water (for vacuum pump)\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003ePipe diameter: DN25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esupply(0.2~0.3Mpa)\u003c\/td\u003e\n\u003ctd\u003e150 kg\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eCompressed air\u003c\/td\u003e\n\u003ctd style=\"font-style: inherit; font-weight: inherit;\"\u003eDiameter: φ6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esupply(0.6~0.8Mpa)\u003c\/td\u003e\n\u003ctd\u003e0.1m³\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" width=\"480x480\" height=\"480x480\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/U3H9KRkdgrA\" width=\"480\" height=\"270\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan data-mce-fragment=\"1\"\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIf you're interested in our products, please feel free to contact us by\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eB\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -183px; top: 28px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40197209751718,"sku":"","price":12000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/DoubleDoorSpiceSterilizerForFoodProcessingFactory2.jpg?v=1624948595"},{"product_id":"water-spray-leakage-detection-ampoule-sterilizer-for-vial","title":"Water Spray Leakage Detection Ampoule Sterilizer For Vial","description":"\u003cstrong\u003eWater Spray Leakage Detection Ampoule Sterilizer For Vial\u003c\/strong\u003e\n\u003cp\u003e\u003cbr\u003eModel: SD-SG\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eGeneral\u003cbr data-mce-fragment=\"1\"\u003eThis SG series adopts cyclical water as sterilization heating carrier and carry out water-pouring sterilizing operation for articles.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eDuring the whole working course, superheated water operates in a relatively sealing cyclical system, which has series of advantages,high heat efficiency, good temperature evenness, stable temperature adjusting range, etc. Besides, this equipment also effectively prevents second pollution during working, with anti-pressure protection device. It can be applied widely to high-and-low temperature sterilizing operation on liquid in glass bottles, ampoule bottles, plastic bottles, plastic packs, etc, in pharmaceutics. Meanwhile, it is also suitable for foodstuff industry to sterilize all kinds of sealing package, drinks, cans.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eAccording to adopting computers and high-performance devices, it increasingly improves the stability and intelligence of the machine, and makes it more suitable for high-intelligent management system of modern workshops. Meanwhile, refined manufacturing, world-famous configurations and good after service make you more satisfactory.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eDocuments\u003cbr data-mce-fragment=\"1\"\u003eFAT, SAT, DQ, IQ, OQ, PQ.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003ePipe System\u003cbr data-mce-fragment=\"1\"\u003ePipe system is consisted of internal circulation and external circulation. The former is sterilizing medium channel, mainly consisted of circulating pump, board type heat exchanger and internal spray system. The latter is “heating” and “cooling” supply channel, consisted of board type heat exchanger\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-a- Pipe connection: connected by flange, the material is SUS304\/316L\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-b- Board type heat exchanger: The producer of the exchanger is ALFALAVAL Sweden which has large quantity of users and good service. It made by 316L stainless steel which is special design for high temperature working condition with high heat efficiency, easy to change the plates, easy clean.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-c- Circulating pump: The producer of the circulated pump is GRANDFOSS Denmark, which working temperature can over 150 ℃. The product is vertical multistage centrifugal pump, which is in low noise, low energy cost, free-maintenance and no leakage. This type product is widely used by national customers and after service net is quite complete.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-d- Spray system: The spray nozzle is produced by Spray Company, USA, and works in big water flux and wide spray angle. A lot of this type spray distributed in the top and side of the chamber can spray the high temperature water into water fog to every corner of the sterilization chamber. It assures the uniformity of the temperature and rapidly cool down the sterilization chamber and materials when needed.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-e- Control valves: The valves are produced by GEMU Company, Germany. The pneumatic water proof hammer angle valve is fixed in cooling water system that the system can work more smoothly. Other valves are heat resistance angle pneumatic valve which are special for steam (180℃). They are bid directional self-adjustable airproof, big flux with 6 million times working life.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-f- Steam trap: Steam trap is the key to control the steam consumption of super water sterilizer which is float-ball type produced by Spirax. sarco Company, UK. It is good at dividing water from steam with long working life.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eControl System\u003cbr data-mce-fragment=\"1\"\u003eThe control system incorporated with: PLC + HIM+ DCS. It can be operated automatically and handly.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-a- The PLC can work over 50 thousand hours without any break down.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e-b- The touch screen is colorful and clearly. The PLC is made by Siemens. which is the first in the PLC field. Because of powerful dynamic function, diagram editing function, communication function and so on.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe PLC has three function of data recording, attaching U card. Even if the host computer is broken, the temperature and pressure data can be also recorded in the card.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eMain Parameters\u003cbr data-mce-fragment=\"1\"\u003e1. design pressure: 0.245Mpa\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e2. design temperature: 139℃\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e3. working pressure: 0~0.22Mpa\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e4. working temperature: 60~134℃\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e5. heat equilibrium: ≤±1℃\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e6. steam pressure: 0.4-0.6Mpa\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e7. tap water pressure: 0.2-0.3Mpa\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e8. compressed air pressure: 0.6-0.8Mpa\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e9. pure water pressure: 0.2-0.3Mpa\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e10. materical: SUS304\/SUS316\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003ciframe width=\"480\" height=\"270\" src=\"https:\/\/www.youtube.com\/embed\/GvAhccZxie4\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers, dry ovens\u003cspan data-mce-fragment=\"1\"\u003e, consumables, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIf you're interested in our products, please feel free to contact us by\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eB\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -214px; top: -20px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40197907611814,"sku":"","price":11518.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/Ampoule-Autoclave-705x705.jpg?v=1622195789"},{"product_id":"200liter-large-vacuum-steam-autoclave-plc-control","title":"200liter Large Vacuum Steam Autoclave PLC Control","description":"200liter Large Vacuum Steam Autoclave PLC Control\u003cbr\u003e\u003cbr\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eModel:SD-VSA-200L\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eSterilizing Volume:200liter\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eFeatures:\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003e1. 3-times pre-vacuum\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e effective discharge cold air from chamber to improve steam efficiency.\u003cbr data-mce-fragment=\"1\"\u003e2. Internal steam generator\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e PLC control\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e space and energy saving.\u003cbr data-mce-fragment=\"1\"\u003e3. The post-sterilization hot steam is cooled down before discharge from machine.\u003cbr data-mce-fragment=\"1\"\u003e4. Equipped with water quality monitor\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e extend the machine service life.\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eBrand: SADA Medical\u003cbr data-mce-fragment=\"1\"\u003eProduct Origin:China\u003cbr data-mce-fragment=\"1\"\u003eShipping Port:Shanghai\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Qingdao\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Ningbo\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Shenzhen\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Guangzhou\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e etc.\u003cbr data-mce-fragment=\"1\"\u003eLead Time\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e：\u003c\/span\u003e20 – 25 working days.\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eVacuum Steam Autoclave\u003cbr data-mce-fragment=\"1\"\u003eThis unit is ideal equipment for clinics\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e hospital\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e scientific research institutes and other organizations to sterilize surgical instruments\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e fabric glassed.culture media etc.\u003cbr data-mce-fragment=\"1\"\u003eVacuum Steam Autoclave Certification: CE mark\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e;\u003c\/span\u003e ISO 13485\u003cbr data-mce-fragment=\"1\"\u003eType: Vacuum Steam Sterilizer Equipment.\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eUses of the Vacuum Steam Autoclave:\u003cbr data-mce-fragment=\"1\"\u003eVacuum Steam Autoclave are widely used in microbiology\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e medicine\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e podiatry\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e tattooing\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e body piercing\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e veterinary science\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e mycology\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e funeral homes\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e dentistry\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e and prosthetics fabrication. They vary in size and function depending on the media to be sterilized. Typical loads include laboratory glassware\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e other equipment and waste\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e surgical instruments and medical waste.\u003cbr data-mce-fragment=\"1\"\u003eSterilization Objects: Unwrapped or Wrapped instruments\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Sugical instruments\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Glassware\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Liquid \u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Culture Media\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Rubber Material\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Gowns\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Dressing\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e Gloves\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e,\u003c\/span\u003e etc.\u003c\/p\u003e\n\u003cp class=\"p1\" data-mce-fragment=\"1\"\u003eAfter-sale Service:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli class=\"p1\" data-mce-fragment=\"1\"\u003e1 year quality guarantee\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e;\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p1\" data-mce-fragment=\"1\"\u003eQuestions response within 24 hours\u003cspan class=\"s1\" data-mce-fragment=\"1\"\u003e;\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p1\" data-mce-fragment=\"1\"\u003eVideo or photos instruction guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"463\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"228\"\u003eCapacity\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e200liter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC380V, 50HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd\u003e0.21-0.23MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Over-pressure\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e1. Over-pressure warning alarm\u003cbr\u003e2. Safe pressure relief valve\u003cbr\u003e3. Over-temperature shut-off device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Door Interlock\u003c\/td\u003e\n\u003ctd width=\"235\"\u003ePLC Set: the door can't open while vessel is under pressure; can't start up if the door is not properly closed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Emergency Shut-off\u003c\/td\u003e\n\u003ctd\u003eIn a readily accessible location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Surfaces\u003c\/td\u003e\n\u003ctd\u003eSurfaces NOT exceeding 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor\u003c\/td\u003e\n\u003ctd width=\"235\"\u003eMechanical rotating locking with electronic sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator For Temperature\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e±1% accuracy over the scale range 50°C to 150°C; 0.1°C resolution for digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Indicators\u003c\/td\u003e\n\u003ctd width=\"235\"\u003eDoor locked, operation in progress, major operating cycle stages, and cycle complete, times, temperature, pressure, fault condition readable by normal vision from a distance of 1.2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManuals\u003c\/td\u003e\n\u003ctd width=\"235\"\u003eEnglish language\u003cbr\u003e1. Operation instructions (including process description)\u003cbr\u003e2. Loading and maintenance procedures\u003cbr\u003e3. Short-form of operation and loading procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare parts (option)\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e1. Heating element\u003cbr\u003e2. Door seal\/ gasket\u003cbr\u003e3. Replacement air filter\u003cbr\u003e4. Safety valve\u003cbr\u003e5. Pressure and temperature gauges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003ciframe width=\"480\" height=\"270\" src=\"https:\/\/www.youtube.com\/embed\/GvAhccZxie4\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan data-mce-fragment=\"1\"\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIf you're interested in our products, please feel free to contact us by\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eB\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40209143169190,"sku":"","price":11926.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/200liter_advanced_vacuum_steam_autoclave_01_1024x1024_2x_c5a7f273-86fb-42bb-84df-afd4288b2cc8.jpg?v=1622429832"},{"product_id":"advanced-100liter-vacuum-steam-autoclave-for-hospital","title":"Advanced 100liter Vacuum Steam Autoclave for Hospital","description":"\u003cp\u003e200liter Large Vacuum Steam Autoclave PLC Control\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eModel:SD-VSA-200L\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eSterilizing Volume:200liter\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eFeatures:\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003e1. 3-times pre-vacuum\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e effective discharge cold air from chamber to improve steam efficiency.\u003cbr data-mce-fragment=\"1\"\u003e2. Internal steam generator\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e PLC control\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e space and energy saving.\u003cbr data-mce-fragment=\"1\"\u003e3. The post-sterilization hot steam is cooled down before discharge from machine.\u003cbr data-mce-fragment=\"1\"\u003e4. Equipped with water quality monitor\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e extend the machine service life.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eBrand: SADA Medical\u003cbr data-mce-fragment=\"1\"\u003eProduct Origin:China\u003cbr data-mce-fragment=\"1\"\u003eShipping Port:Shanghai\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Qingdao\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Ningbo\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Shenzhen\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Guangzhou\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e etc.\u003cbr data-mce-fragment=\"1\"\u003eLead Time\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e：\u003c\/span\u003e20 – 25 working days.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eVacuum Steam Autoclave\u003cbr data-mce-fragment=\"1\"\u003eThis unit is ideal equipment for clinics\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e hospital\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e scientific research institutes and other organizations to sterilize surgical instruments\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e fabric glassed.culture media etc.\u003cbr data-mce-fragment=\"1\"\u003eVacuum Steam Autoclave Certification: CE mark\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e;\u003c\/span\u003e ISO 13485\u003cbr data-mce-fragment=\"1\"\u003eType: Vacuum Steam Sterilizer Equipment.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eUses of the Vacuum Steam Autoclave:\u003cbr data-mce-fragment=\"1\"\u003eVacuum Steam Autoclave are widely used in microbiology\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e medicine\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e podiatry\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e tattooing\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e body piercing\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e veterinary science\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e mycology\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e funeral homes\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e dentistry\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e and prosthetics fabrication. They vary in size and function depending on the media to be sterilized. Typical loads include laboratory glassware\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e other equipment and waste\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e surgical instruments and medical waste.\u003cbr data-mce-fragment=\"1\"\u003eSterilization Objects: Unwrapped or Wrapped instruments\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Sugical instruments\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Glassware\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Liquid \u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Culture Media\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Rubber Material\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Gowns\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Dressing\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e Gloves\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e,\u003c\/span\u003e etc.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\" class=\"p1\"\u003eAfter-sale Service:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\" class=\"p1\"\u003e1 year quality guarantee\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e;\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" class=\"p1\"\u003eQuestions response within 24 hours\u003cspan data-mce-fragment=\"1\" class=\"s1\"\u003e;\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" class=\"p1\"\u003eVideo or photos instruction guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"463\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"228\"\u003eCapacity\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e200liter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eAC380V, 50HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd\u003e0.21-0.23MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Over-pressure\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e1. Over-pressure warning alarm\u003cbr\u003e2. Safe pressure relief valve\u003cbr\u003e3. Over-temperature shut-off device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Door Interlock\u003c\/td\u003e\n\u003ctd width=\"235\"\u003ePLC Set: the door can't open while vessel is under pressure; can't start up if the door is not properly closed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Emergency Shut-off\u003c\/td\u003e\n\u003ctd\u003eIn a readily accessible location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Surfaces\u003c\/td\u003e\n\u003ctd\u003eSurfaces NOT exceeding 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor\u003c\/td\u003e\n\u003ctd width=\"235\"\u003eMechanical rotating locking with electronic sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator For Temperature\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e±1% accuracy over the scale range 50°C to 150°C; 0.1°C resolution for digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Indicators\u003c\/td\u003e\n\u003ctd width=\"235\"\u003eDoor locked, operation in progress, major operating cycle stages, and cycle complete, times, temperature, pressure, fault condition readable by normal vision from a distance of 1.2m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManuals\u003c\/td\u003e\n\u003ctd width=\"235\"\u003eEnglish language\u003cbr\u003e1. Operation instructions (including process description)\u003cbr\u003e2. Loading and maintenance procedures\u003cbr\u003e3. Short-form of operation and loading procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare parts (option)\u003c\/td\u003e\n\u003ctd width=\"235\"\u003e1. Heating element\u003cbr\u003e2. Door seal\/ gasket\u003cbr\u003e3. Replacement air filter\u003cbr\u003e4. Safety valve\u003cbr\u003e5. Pressure and temperature gauges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ciframe width=\"480\" height=\"270\" src=\"https:\/\/www.youtube.com\/embed\/6TQ3DxEtnnk\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan data-mce-fragment=\"1\"\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIf you're interested in our products, please feel free to contact us by\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eB\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40209156800678,"sku":"","price":10298.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/automatic_door_sterilization_machine.jpg?v=1634611295"},{"product_id":"horizontal-autoclave-steam-sterilizer-ha-ba","title":"Sada Medical HA-BA Horizontal Cylindrical Steam Sterilizer – 150L \/ 200L \/ 280L | Class N, Digital Display, Printer \u0026 Drying","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReliable High-Volume Sterilization With Advanced Safety, Every Cycle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhen your hospital, laboratory, or pharmaceutical facility processes large loads of surgical instruments, textiles, glassware, or culture media, you need a sterilizer that runs consistently and protects your operators at every step. The\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSada Medical HA-BA Horizontal Cylindrical Pressure Steam Autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecombines a spacious chamber, microprocessor-controlled automation, and multiple independent safety systems into a single dependable unit. Whether you choose the 150L, 200L, or 280L model, you get a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass N steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethat is built to keep your sterilization room running efficiently without demanding constant supervision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe HA-BA’s digital display and computer-controlled cycles take the guesswork out of sterilization: simply load your instruments, select the time and temperature, and press start. A built-in drying phase (0–99 minutes adjustable) ensures that dressings, gowns, and wrapped packs emerge dry, while the integrated printer records every cycle for your infection control documentation. With a 304 stainless steel chamber, a safety interlock door, and automatic over-temperature and over-pressure protection, the HA-BA is designed to be the safe, reliable core of your\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emedical instrument disinfection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eworkflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"ds-markdown-paragraph\"\u003eOverall display of the SADA horizontal sterilizer\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/16EkRrUiclc\" title=\"🖨️ HA-BA Horizontal Steam Autoclave with Drying \u0026amp; Printer | 150L-280L for CSSD \u0026amp; Hospital #shorts\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat Makes the HA-BA a Smarter Sterilization Choice\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFully Automatic Digital Control\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe HA-BA is managed by a microprocessor that automates the entire sterilization cycle: water fill, heating, sterilization, steam exhaust, and drying. The bright digital display shows real-time temperature and remaining time, and touch-type keys make it easy to set parameters from 40°C to 134°C, with sterilization and drying timers adjustable from 0 to 99 minutes. This\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomputer controlled autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereduces the training burden and minimizes operator error.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIntegrated Drying Function\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eUnlike basic sterilizers that leave packs wet, the HA-BA includes a dedicated drying phase. After the sterilization plateau, residual heat dries the load, making it suitable for sterilizing gowns, drapes, dressings, and wrapped surgical packs that must be stored dry. This\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehorizontal autoclave with drying\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis especially valuable in hospital CSSD and surgical centers where wet packs compromise sterility.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e304 Stainless Steel Chamber \u0026amp; Robust Build\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe cylindrical chamber is made of 304 stainless steel, resistant to corrosion from repeated steam exposure and disinfection cleaning. Combined with a sturdy outer structure, this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehorizontal pressure steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built to withstand the demands of a busy sterilization department for years.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Interlock Door You Can Trust\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe door cannot be opened until the chamber pressure drops to or below 0.027 MPa, preventing accidental steam release. Likewise, the cycle will not start if the door isn’t properly sealed. This mechanical and electronic interlock system is essential for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh pressure sterilizer safety\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, protecting operators and ensuring every cycle runs under correct conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti-Layer Over-Pressure \u0026amp; Over-Temperature Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIf the internal pressure exceeds 0.24 MPa, the safety valve opens automatically and vents steam to the water link. If the temperature controller malfunctions, independent over-temperature protection cuts the heater. Should the machine run low on water, the power cuts off automatically, the water supply is shut, and an alarm sounds. There’s also heater protection, anti-dry heating, and electric safety protective devices—seven independent safety layers in total.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eBuilt-in Printer for Effortless Traceability\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eEvery cycle is documented automatically: date, time, temperature, and pressure are printed on the integrated thermal printer. For hospital CSSDs, dental clinics, and pharmaceutical labs that must demonstrate\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esterilization monitoring and infection control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecompliance, this eliminates manual logs and creates a reliable paper trail.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePrecise Temperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe HA-BA maintains temperature distribution within ≤ ±1°C across the chamber, critical for effective sterilization of porous loads, liquid media, and hollow instruments. This level of uniformity is a hallmark of a properly engineered\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elaboratory sterilizer and medical autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCE \u0026amp; ISO 13485 Certified\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eManufactured under Sada Medical’s\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEN ISO 13485:2016\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003equality management system and CE marked, the HA-BA meets international medical device standards for safety and performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWho Uses the HA-BA Horizontal Autoclave?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge capacity steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis right at home in any facility that processes substantial loads of wrapped or unwrapped instruments and materials:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHospital CSSD \u0026amp; Surgical Centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– wrapped trays, gowns, drapes, rubber goods, and dressings\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDental Clinics \u0026amp; Dental Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– bulk instrument processing, impression trays, and wrapped handpiece sets\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePharmaceutical \u0026amp; Biotech Facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– glassware, liquid media, and cleanroom garments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVeterinary Hospitals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– surgical packs, animal care tools, and rubber mats\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMicrobiology \u0026amp; Research Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– culture media, test tubes, Petri dishes, and bio-waste\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eTattoo \u0026amp; Piercing Studios\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– bulk sterilization of tubes, grips, and needle bars\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFuneral Homes \u0026amp; Prosthetics Fabrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reusable instruments and porous materials\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIf you’re searching for a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003ehorizontal autoclave for hospitals\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003eClass N steam sterilizer with printer and drying\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, or a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003elarge CSSD sterilizer with safety interlocks\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, the HA-BA is engineered to meet your daily sterilization demands.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BA150\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BA200\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BA280\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e150 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e200 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e280 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Size (Ø × H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ440 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ515 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ600 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSterilization Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrying Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380V 50Hz (220\/380V, 50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380V 50Hz (220\/380V, 50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 kW \/ AC 380V 50Hz (220\/380V, 50\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContact us for exact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContact us for exact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContact us for exact dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e*\u003cspan class=\"\"\u003eAll models include digital display, computer control, 304 stainless steel chamber, safety interlock door, drying function, built-in printer, automatic safety valve, water-shortage alarm, and multiple safety protections.\u003c\/span\u003e*\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat’s Included with Your HA-BA Sterilizer\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical HA-BA horizontal cylindrical pressure steam autoclave (choose 150L, 200L, or 280L)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBuilt-in mini printer with starter paper roll\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStainless steel loading trays\/baskets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower cable and water connection kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eComprehensive user manual and access to our online operation video guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eAfter-Sales Support You Can Count On\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical backs every HA-BA sterilizer with a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-month warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand a technical support team that responds within 24 hours. Have a question about cycle programming, safety interlocks, or routine maintenance? We offer video or photo guidance to walk you through any step. With exports to healthcare providers in over 50 countries, we understand that reliable\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautoclave sterilization support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis just as important as the machine itself.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get Your Quote \u0026amp; Expert Support in One Click\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eTalk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp 按钮 --\u003e \u003ca href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BA%20horizontal%20steam%20autoclave\" style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- 官网详细询盘按钮 --\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/contact\" style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- 产品目录下载按钮 --\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"HA-BA150","offer_id":40222699258022,"sku":"","price":4663.94,"currency_code":"USD","in_stock":true},{"title":"HA-BA200","offer_id":57473796636838,"sku":null,"price":5441.26,"currency_code":"USD","in_stock":true},{"title":"HA-BA280","offer_id":57473796669606,"sku":null,"price":6443.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Main-06_28cb4277-a6b3-4065-8092-dd2923d3de3a.jpg?v=1779437474"},{"product_id":"stainless-steel-steam-autoclave-machine-ha-bd","title":"Sada Medical HA-BD Series Stainless Steel High-Pressure Steam Autoclave – 150L \/ 200L \/ 280L | Built-in Drying \u0026 Advanced Safety Interlocks","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeavy-Duty Sterilization That Puts Safety First\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIn a busy hospital CSSD, dental clinic, or research lab, steam sterilization is routine—but the risks of pressure equipment are real. The\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSada Medical HA-BD Stainless Steel High-Pressure Steam Autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered with multiple independent safety layers that protect your staff and your facility at every stage of the cycle. From the door interlock that prevents steam entry until the door is fully sealed, to the automatic pressure-lock that keeps the door closed until the chamber drops below 0.027 MPa, the HA-BD eliminates the kind of operator errors that lead to accidents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAvailable in\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e150L, 200L, and 280L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echamber capacities, this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehorizontal pressure steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehandles the large loads that central sterile supply departments, veterinary hospitals, and microbiology labs depend on. A built-in drying function, automatic cool-air exhaust, and full stainless steel construction make it a reliable, low-maintenance core piece of your\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edisinfection and sterilization equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003elineup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIf you’ve been looking for a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003elarge capacity autoclave with drying\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethat won’t compromise on safety, the HA-BD series is ready for the demands of your daily instrument processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhy the HA-BD Is Engineered Differently\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMultiple Safety Interlocks Protect Your Team\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eSteam cannot enter the chamber until the door is fully closed and sealed. If the door isn’t properly latched, the pilot light remains off and steam is blocked from the jacket and chamber. Once the internal pressure exceeds 0.027 MPa, the door locks automatically and cannot be opened until the pressure drops to a safe level. If an operator accidentally attempts to open the door during a running cycle, the jacket valve closes immediately and the chamber valve opens to release residual pressure—preventing a dangerous steam burst.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eBuilt-in Drying Function for Wrapped Goods and Textiles\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eAfter the sterilization phase completes, the drying timer (adjustable from 0 to 60 minutes) uses residual chamber heat to dry gowns, dressings, wraps, and porous loads. This keeps your sterile packs dry and ready for storage, reducing the risk of recontamination from moisture. The drying phase runs entirely without steam discharge, keeping your workspace clean and comfortable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic Water-Shortage and Overload Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIf the water level drops too low, the HA-BD automatically switches on the water-shortage pilot light, cuts power to the heating element and the sterilization pilot, sounds a buzzer alarm, and releases steam safely. There’s no risk of a dry-running heater. In addition, an overload and leakage protection system cuts power instantly if excessive current or electrical leakage is detected. This\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emedical steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built to safeguard both the operator and the building’s electrical system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIndependent Safety Valve for Over-Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eShould the temperature controller ever malfunction and internal pressure rise above 0.165 MPa, the mechanical safety valve opens automatically and releases steam to the water line. This redundant mechanical backup operates independently of the electronic control system—a critical feature for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehospital sterilization equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethat runs unattended cycles overnight.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFully Stainless Steel Structure\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe chamber, door, and exterior housing are all constructed from corrosion-resistant stainless steel. There are no painted surfaces to peel after repeated exposure to steam, disinfectants, or humidity. This\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully stainless steel steam autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis designed to look professional and perform reliably in the busiest environments for years.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eStraightforward, Reliable Control\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe HA-BD uses a simple panel with indicator lights that show the current cycle status at a glance. Temperature and sterilization\/dry timers are adjustable (40°C–134°C, 0–60 minutes each), and an automatic buzzer signals cycle completion. The system also exhausts cool air at the beginning of each cycle for effective steam penetration—no manual valves required.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCE \u0026amp; ISO 13485 Certified Quality\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eManufactured under Sada Medical’s\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEN ISO 13485:2016\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003equality system and carrying the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the HA-BD meets international medical device safety and performance standards. It’s a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehospital autoclave machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eyou can integrate into your CSSD or clinic with confidence.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWho Uses the HA-BD Horizontal Autoclave?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge-capacity steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis purpose-built for high-volume processing of wrapped and unwrapped instruments, textiles, and media:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHospital CSSD Departments \u0026amp; Surgical Centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– wrapped surgical trays, gowns, drapes, rubber goods, and dressings\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVeterinary Hospitals \u0026amp; Animal Research\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– surgical packs, cages, feeding equipment, and rubber mats\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDental Clinics \u0026amp; Dental Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– bulk instrument processing, impression trays, and wrapped handpiece kits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMicrobiology, Life Science \u0026amp; Pharmaceutical Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– culture media, glassware, liquid reagents, and biohazard waste\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eTattoo \u0026amp; Body Piercing Studios\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– grip tubes, needle bars, and wrapped jewelry packs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFuneral Homes \u0026amp; Prosthetics Fabrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reusable instruments and dressing materials\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eResearch Institutes \u0026amp; Universities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– laboratory consumables, discard cycles, and media preparation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIf you’ve been searching for a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003ehigh capacity horizontal autoclave for hospitals\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003estainless steel CSSD sterilizer with drying\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, or a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003epressure steam sterilizer for surgical instruments\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, the HA-BD delivers the safety and capacity your facility requires.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BD150\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BD200\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BD280\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e150 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e200 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e280 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Size (Ø × H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ440 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ515 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ600 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40 – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40 – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40 – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSterilization Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 60 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 60 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 60 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrying Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 60 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 60 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 60 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±2°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±2°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±2°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380V, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380V, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 kW \/ AC 380V, 50Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1400 × 650 × 1600 mm*\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1400 × 750 × 1700 mm*\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1520 × 910 × 1900 mm*\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNet Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e340 kg*\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e350 kg*\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e462 kg*\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003e\u003cspan class=\"\"\u003eApproximate dimensions and weights; please confirm with our team when ordering. All models include safety interlock door, water-shortage alarm, over-pressure safety valve, overload protection, drying function, and full stainless steel body.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat’s Included with Your HA-BD Autoclave\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical HA-BD horizontal pressure steam sterilizer (select 150L, 200L, or 280L)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStainless steel loading baskets or shelves (configuration suited to model)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower cable and water connection kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDetailed user manual and access to Sada Medical’s online installation and operation video library\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eAfter-Sales Support That Keeps You Running\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical backs every HA-BD sterilizer with a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1-year quality guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand a responsive support team. Have a question about installation, cycle settings, or routine maintenance? We reply within 24 hours and offer video or photo instruction to guide you step by step. We’ve supplied\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esteam autoclaves to healthcare providers, labs, and clinics worldwide\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—and we understand that downtime isn’t an option when your facility relies on a single sterilizer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get Your Quote \u0026amp; Expert Support in One Click\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eTalk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp 按钮 --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BD%20large%20capacity%20steam%20autoclave\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- 官网详细询盘按钮 --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/contact\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- 产品目录下载按钮 --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40222761975974,"sku":"","price":11538.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/autoclave.png?v=1622443086"},{"product_id":"stainless-steel-high-pressure-steam-sterilizer-ha-bb","title":"Sada Medical HA-BB Series Fully Stainless Steel High-Pressure Steam Sterilizer (150L \/ 200L \/ 280L) – Built-in Printer \u0026 Drying Function","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReliable Large-Capacity Steam Sterilization for Hospitals, CSSDs \u0026amp; Busy Clinics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhen your facility processes a high volume of surgical instruments, wrapped gowns, culture media, or glassware every day, downtime isn’t an option. The Sada Medical HA-BB horizontal\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh pressure steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003egives you repeatable, 134°C saturated-steam cycles in a fully automatic package—backed by a rugged full stainless steel body that stands up to years of demanding use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAvailable in\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e150L, 200L, and 280L\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echamber capacities, this\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epressure steam sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built for central sterile supply departments (CSSD),\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edental sterilizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eupgrades, medical device disinfection clinics, prosthetic labs, and veterinary hospitals. Every cycle finishes with dry, ready-to-use instruments, thanks to the integrated drying phase and precise thermal control.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhy Professionals Choose the HA-BB Autoclave\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTrue Hands-Off Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe automatic cycle controls fill, sterilizing, exhausting, and drying. Load your instruments, close the door, and press start—the machine does the rest. Adjustable sterilization time (0–99 min) and drying time (0–99 min) let you tailor cycles to wrapped instruments, rubber goods, or liquid media without guessing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBuilt-in Printer for Standardized Records\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA thermal printer logs date, time, chamber temperature, and pressure for every cycle. If you need traceability for infection control audits or hospital CSSD documentation, this feature saves time and eliminates manual logs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMedical-Grade Safety \u0026amp; Interlock Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe door cannot be opened until the chamber pressure drops below 0.027 MPa—and the cycle won’t start unless the door is fully sealed. Should the internal pressure exceed 0.24 MPa, the safety valve opens automatically to vent steam. Over-temperature protection, over-pressure cut-off, and a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewater-shortage alarm with automatic power shut-off\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eadd layers of operator safety that hospitals and laboratories depend on.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFully Stainless Steel Construction\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eBoth the sterilization chamber and the exterior housing are made of corrosion-resistant stainless steel. No painted surfaces to peel, no plastic panels to degrade after repeated disinfection wipe-downs. This sterilizer is built to stay clean and professional year after year.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExcellent Temperature Uniformity (≤ ±2°C)\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eWhether you’re sterilizing porous loads, hollow surgical instruments, or unwrapped glassware, tight temperature distribution means consistent lethality across the entire 440–600mm diameter chamber—exactly what microbiologists and sterile processing technicians look for in a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emedical equipment autoclave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE \u0026amp; ISO 13485 Certified Manufacturing\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe HA-BB series is produced under our certified EN ISO 13485:2016 quality management system and carries the CE mark. It’s a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edisinfection and sterilization equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esolution you can confidently add to any healthcare facility’s instrument processing workflow.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/afecQHj3r4Q\" title=\"🖨️ HA-BB Horizontal Steam Sterilizer with Drying \u0026amp; Printer | 150L-280L for CSSD \u0026amp; Hospital #shorts\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWho Uses This Pressure Steam Autoclave?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe HA-BB is designed for anyone who needs reliable sterilization mid- to high-volume loads:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHospital CSSD \u0026amp; Surgical Centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– sterilizing wrapped surgical trays, gowns, drapes, and unwrapped instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDental Clinics \u0026amp; Dental Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– safe sterilization of dental handpieces, forceps, and impression trays\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMicrobiology \u0026amp; Life Science Labs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– liquid media, culture plates, contaminated glassware, and bio-waste\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVeterinary Hospitals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– surgical packs and animal care tools\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eTattoo \u0026amp; Body Piercing Studios\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– tube sets, needle bars, tweezers, and grips under strict hygiene codes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFuneral Homes \u0026amp; Prosthetics Fabrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reusable devices and dressing materials\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIf you’ve been searching for a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003elarge capacity autoclave with drying\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003ehospital grade steam sterilizer\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, or a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003e\u003cspan class=\"\"\u003estainless steel autoclave with printer\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e, the HA-BB series is engineered to meet your daily demands.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BB150\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BB200\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eHA-BB280\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e150 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e200 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e280 Liters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChamber Size (Ø × H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ440 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ515 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eØ600 × 1000 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.22 MPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40°C – 134°C adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSterilization Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrying Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0 – 99 minutes adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±2°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±2°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤ ±2°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 kW \/ AC 380 V, 50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e9 kW \/\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC 220 V, 50 Hz\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 kW \/ AC 380 V, 50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOverall Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1400 × 650 × 1600 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1400 × 750 × 1700 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1520 × 910 × 1900 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNet Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e340 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e350 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e462 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003e\u003cspan class=\"\"\u003eAll models include a built-in printer, automatic safety valve, door safety interlock, and over-temperature\/over-pressure alarm system.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eWhat’s Included?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSada Medical HA-BB pressure steam sterilizer (choose your capacity)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBuilt-in cycle printer with starter paper roll\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStainless steel loading baskets or shelves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower cable and water connection kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDetailed user manual and access to our online video setup guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003eAfter-Sales Support That Keeps You Running\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWe stand behind every sterilizer with a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1‑year quality guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand a support team that responds to questions within 24 hours. Need help choosing between the 150L, 200L, or 280L model? We’ll walk you through your typical load list over a video call to make sure you get the right chamber size and voltage version. From installation tips to periodic checks, Sada Medical’s technical support is just a message away.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get Your Quote \u0026amp; Expert Support in One Click\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eTalk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp 按钮 --\u003e \u003ca href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BB%20high%20pressure%20steam%20sterilizer\" style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- 官网详细询盘按钮 --\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/contact\" style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- 产品目录下载按钮 --\u003e \u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":40222799757478,"sku":"","price":8601.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/products\/HA-BB-STERILIZER-AUTOCLAVE.jpg?v=1624949115"},{"product_id":"100l-150l-200l-300l-ha-bav-vacumm-horizontal-autoclave","title":"HA-BAV Series Vacuum Horizontal Autoclave – 100L \/ 150L \/ 200L \/ 300L High Pressure Steam Sterilizer with Touch Screen \u0026 Printer for Hospital CSSD","description":"\u003cdiv style=\"font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; line-height: 1.5; color: #2c3e4f; max-width: 100%;\"\u003e\n\u003c!-- Overview Section --\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eFor \u003cstrong\u003ehospital CSSD (Central Sterile Supply Department)\u003c\/strong\u003e, large surgical centers, and pharmaceutical cleanrooms that demand high-throughput sterilization with complete validation, the \u003cstrong\u003eSADA Medical HA-BAV series vacuum horizontal autoclave\u003c\/strong\u003e delivers industrial-grade performance. With chamber capacities ranging from \u003cstrong\u003e100L to 300L\u003c\/strong\u003e, this \u003cstrong\u003ehigh pressure vacuum steam sterilizer\u003c\/strong\u003e features \u003cstrong\u003e3+ pulsating vacuum cycles\u003c\/strong\u003e for superior air removal – ensuring steam penetration into \u003cstrong\u003ewrapped instruments, hollow lumens, porous loads, and internal pipeline instruments\u003c\/strong\u003e. The \u003cstrong\u003e7-inch color touch screen\u003c\/strong\u003e with microcomputer control offers \u003cstrong\u003e6+ sterilization programs\u003c\/strong\u003e, built-in \u003cstrong\u003eprinter for full cycle documentation\u003c\/strong\u003e, \u003cstrong\u003eBowie \u0026amp; Dick test function\u003c\/strong\u003e, and \u003cstrong\u003edeep drying capability\u003c\/strong\u003e. Built with a \u003cstrong\u003ecircular double-layer chamber (sterilization chamber + jacket)\u003c\/strong\u003e and constructed from \u003cstrong\u003ehigh-quality stainless steel\u003c\/strong\u003e, the HA-BAV is the backbone of any modern \u003cstrong\u003einfection control equipment\u003c\/strong\u003e strategy. Whether you manage a busy CSSD or a pharmaceutical production line, the HA-BAV ensures consistent, validated sterilization results – day after day.\u003c\/p\u003e\n\u003c!-- Video Embed Placeholder (replace with actual embed code) --\u003e\n\u003cdiv style=\"margin: 30px 0; padding: 20px; background: #fafcfd; border: 2px dashed #2c7da0; border-radius: 20px; text-align: center;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; color: #1e3a5f;\"\u003eProduct Video – HA-BAV Horizontal Vacuum Autoclave in Action\u003c\/h4\u003e\n\u003cp style=\"margin: 0 0 12px 0; font-size: 14px; color: #4a627a;\"\u003eWatch the touch screen operation, pulse vacuum cycle, printer output, and door safety system.\u003c\/p\u003e\n\u003c!-- PASTE YOUR VIDEO EMBED CODE INSIDE THIS DIV --\u003e\n\u003cdiv style=\"background: #e9edf2; border-radius: 12px; padding: 40px 20px; color: #6c7e8f; font-size: 14px;\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/4ocRz01F7cc\" title=\"7 Units of HA-BAV 300L Sterilizers Ready for Austria | Quality Control \u0026amp; Packaging\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Key Features Grid --\u003e\n\u003cdiv style=\"background: #f1f5f9; border-radius: 16px; padding: 20px; margin: 30px 0;\"\u003e\n\u003ch2 style=\"color: #1e3a5f; margin-top: 0; font-size: 22px; border-left: 4px solid #2c7da0; padding-left: 15px;\"\u003e⚙️ Why Large Healthcare Facilities Choose the HA‑BAV Vacuum Autoclave\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; margin-top: 15px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📱 7\" Color Touch Screen\u003c\/strong\u003e\u003cbr\u003eMicro-computer automatically controls the sterilization process – no need for supervision. Displays time, pressure, temperature, and cycle status.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔄 3+ Pulse Vacuum Technology\u003c\/strong\u003e\u003cbr\u003eSuitable for packed, unpacked, hollow porous, and internal pipeline instruments – complete air removal every time.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📄 Built-in Printer + B\u0026amp;D Test\u003c\/strong\u003e\u003cbr\u003ePrinter records the entire sterilization process. Bowie \u0026amp; Dick test function verifies steam penetration – full traceability.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔧 Double-Layer Chamber + Jacket\u003c\/strong\u003e\u003cbr\u003eCircular double-layer design (sterilization chamber + jacket) with deep drying function – better temperature uniformity.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e⚙️ 6+ Sterilization Programs\u003c\/strong\u003e\u003cbr\u003eChoose the program according to the objects being sterilized – fabric, instruments, liquids, plastics, custom cycles.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🛡️ Multiple Safety Protections\u003c\/strong\u003e\u003cbr\u003eOver-temperature, over-pressure, low water level, over-current protection + safety interlock door system.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🚪 Safe Door System\u003c\/strong\u003e\u003cbr\u003eManual door with radial rod rotary table type, two-stage self-locking, interlock safety device. Single door (double door pass-through optional).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Specifications Table --\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 30px 0 10px 0;\"\u003e📋 Technical Specifications – HA‑BAV Series (100L – 300L)\u003c\/h2\u003e\n\u003cp\u003eEngineered for high-volume sterilization in demanding environments. The sterilization chamber is made of \u003cstrong\u003ehigh-quality stainless steel\u003c\/strong\u003e with a circular double-layer design. Below are the complete specifications for all models.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: white; border-radius: 16px; overflow: hidden; box-shadow: 0 1px 3px rgba(0,0,0,0.1);\"\u003e\n\u003cthead style=\"background: #1e3a5f; color: white;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BAV100\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BAV150\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BAV200\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eHA‑BAV300\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eChamber Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e100L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e150L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e200L\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e300L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eChamber Size (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eΦ440 × 670\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eΦ440 × 1000\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eΦ515 × 1000\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eΦ600 × 1080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax Working Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax Working Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e115 – 134°C (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSterilization Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e0 – 99 minutes (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDrying Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e0 – 99 minutes (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHeat Average\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e≤ ±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVacuum Limit\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"4\"\u003e-0.08 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower \/ Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\" colspan=\"3\"\u003e10kW \/ AC 380V 50Hz\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e13kW \/ AC 380V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOverall Size (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1400×660×1640\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1400×660×1640\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1400×750×1740\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1520×850×1850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Size (mm)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1560×820×1820\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1560×820×1820\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1560×910×1880\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1680×1080×2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGross Weight (KG)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e430\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e440\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e460\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight (KG)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e340\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e350\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e370\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef9e6; padding: 12px 18px; border-radius: 12px; margin: 10px 0;\"\u003e\n\u003cp style=\"margin: 4px 0;\"\u003e\u003cstrong\u003e🌟 Pulse Vacuum Advantage:\u003c\/strong\u003e The HA-BAV series performs 3 or more pulsating vacuum cycles before steam injection. This removes virtually all air from the chamber and load – ensuring steam penetrates wrapped instruments, hollow devices, porous materials, and internal pipelines.\u003cbr\u003e\u003cstrong\u003e🌟 Built-in Steam Generator:\u003c\/strong\u003e No external steam supply needed. One set of movable sterilization plates is randomly adapted.\u003cbr\u003e\u003cstrong\u003e🌟 Deep Drying Function:\u003c\/strong\u003e The double-layer chamber design (sterilization chamber + jacket) provides excellent drying results – instruments come out dry and ready for storage or use.\u003cbr\u003e\u003cstrong\u003e🌟 What's included:\u003c\/strong\u003e Horizontal autoclave, movable sterilization plates\/trays, printer (built-in), user manual, and test interface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Sterilization Programs \u0026 Applications --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin: 35px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e📋 Sterilization Programs (6+ Types)\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFabric\/Textile Program\u003c\/strong\u003e – For gowns, drapes, and surgical linens\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrument Program\u003c\/strong\u003e – For wrapped and unwrapped surgical instruments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Program\u003c\/strong\u003e – For culture media, solutions, and pharmaceutical liquids\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlastic\/Rubber Program\u003c\/strong\u003e – For heat-sensitive materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u0026amp;D Test Program\u003c\/strong\u003e – For steam penetration validation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Test Program\u003c\/strong\u003e – For chamber integrity verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom User-Defined Program\u003c\/strong\u003e – For specialized loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e🏥 Primary Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospital CSSD\u003c\/strong\u003e – Central Sterile Supply Department\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgical centers \u0026amp; operating rooms\u003c\/strong\u003e – High-volume instrument reprocessing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical factories\u003c\/strong\u003e – Cleanroom equipment and tool sterilization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch laboratories \u0026amp; universities\u003c\/strong\u003e – Biohazardous waste, glassware, media\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDental \u0026amp; veterinary clinics\u003c\/strong\u003e – Large-scale instrument sterilization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuneral homes \u0026amp; prosthetics fabrication\u003c\/strong\u003e – Specialized load processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Safety Protection Details --\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 20px 0 10px 0;\"\u003e🛡️ Complete Safety Protection System\u003c\/h2\u003e\n\u003cdiv style=\"background: #f8fafc; border-radius: 16px; padding: 20px; margin: 15px 0 25px 0;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor Safety Interlock:\u003c\/strong\u003e When door is not closed tightly, steam cannot enter – alarm sounds. When chamber pressure \u0026gt;0.027MPa, door is locked and cannot be opened.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Pressure Protection:\u003c\/strong\u003e Safety valve automatically releases pressure if working pressure is exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Water Level Protection:\u003c\/strong\u003e Unit cannot start until proper water level is reached; automatically cuts off when low water is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Current Protection:\u003c\/strong\u003e Power circuit breaker automatically cuts power supply on current overload.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 15px; margin-bottom: 0;\"\u003e\u003cstrong\u003eSealing Door:\u003c\/strong\u003e Manual door opening\/closing, radial rod rotary table type. Equipped with two-stage self-locking, interlock safety device, and pressure safety interlock. \u003cstrong\u003eDouble-door pass-through option available\u003c\/strong\u003e for cleanroom\/dirty side separation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Quality \u0026 Factory Introduction --\u003e\n\u003cdiv style=\"background: #f0f7f4; border-radius: 16px; padding: 20px; margin: 20px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e✅ SADA Medical – Quality \u0026amp; Certifications\u003c\/h3\u003e\n\u003cp\u003eSADA Medical Co., Ltd. is a professional manufacturer and supplier of \u003cstrong\u003esteam autoclaves, low-temperature plasma sterilizers, ethylene oxide sterilizers, dry ovens, and consumables\u003c\/strong\u003e, exporting to over 80 countries worldwide. We are certified under \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eEN ISO 13485:2016\u003c\/strong\u003e (Medical Devices). The HA-BAV series \u003cstrong\u003evacuum horizontal autoclave\u003c\/strong\u003e is factory-tested with cycle validation reports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy customers trust SADA Medical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin-top: 5px;\"\u003e\n\u003cli\u003eFactory-direct pricing – no middleman markup\u003c\/li\u003e\n\u003cli\u003eOEM\/private labeling available for volume orders\u003c\/li\u003e\n\u003cli\u003e12-month warranty + 24-hour technical support\u003c\/li\u003e\n\u003cli\u003eFast worldwide shipping from Shanghai, Ningbo, Qingdao ports\u003c\/li\u003e\n\u003cli\u003eDouble-door pass-through configuration available on request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e📄 Download the full catalog, user manual, and validation guide using the blue button below.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- CTA Button Block (WhatsApp prefill updated for HA-BAV) --\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Ready to Order the HA‑BAV Vacuum Autoclave?\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eContact us for factory pricing, OEM service, and fast worldwide shipping. Talk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp button (prefill for HA-BAV) --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BAV%20vacuum%20horizontal%20autoclave\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- Website inquiry button --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/contact\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- Catalog download button --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6c7e8f; margin-top: 20px; text-align: center;\"\u003e✔ HS Code 8419200000 – Vacuum horizontal sterilizers for medical, surgical, and laboratory use.\u003cbr\u003e✔ 3+ pulse vacuum technology – suitable for packed, hollow porous, and internal pipeline instruments.\u003cbr\u003e✔ 12-month warranty, 24-hour technical support, and spare parts availability.\u003cbr\u003e✔ Built-in printer for complete cycle documentation + Bowie \u0026amp; Dick test function.\u003cbr\u003e✔ Double-layer chamber with jacket – deep drying function included.\u003cbr\u003e✔ Double-door (pass-through) configuration available for cleanroom applications.\u003cbr\u003e✔ Power requirement: AC 380V 50Hz three-phase – please confirm your facility's power supply.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"HA-BAV100","offer_id":44412931408038,"sku":null,"price":6239.04,"currency_code":"USD","in_stock":true},{"title":"HA-BAV150","offer_id":57473802338470,"sku":null,"price":7363.2,"currency_code":"USD","in_stock":true},{"title":"HA-BAV200","offer_id":57473802371238,"sku":null,"price":8591.47,"currency_code":"USD","in_stock":true},{"title":"HA-BAV300","offer_id":57473802404006,"sku":null,"price":9614.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/HA-BAV_Vacuum_Horizontal_Autoclave_100-300L_High_Pressure_Steam_Sterilizer_for_CSSD-17.png?v=1779935151"},{"product_id":"ts-ddv-100l-small-horizontal-type-autoclave","title":"TS-DDV 100L Small horizontal type autoclave","description":"\u003cp data-mce-fragment=\"1\"\u003eTS-DDV 100L Small horizontal type autoclave\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSteam Pressure Sterilizer Model:TS-DDV\u003cbr data-mce-fragment=\"1\"\u003eSteam Pressure Sterilizer Volume:100L\u003c\/p\u003e\n\u003cp\u003eMedical Instrument Sterilization Autoclave are widely used in microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, and prosthetics fabrication.\u003c\/p\u003e\n\u003cp\u003eThey vary in size and function depending on the media to be sterilized. Typical loads include laboratory glassware, other equipment and waste, surgical instruments and medical waste.\u003c\/p\u003e\n\u003cp\u003eSterilization Objects: Unwrapped or Wrapped instruments, Sugircal instruments, Glassware, Liquid , Culture Media, Rubber Material, Gowns, Dressing, Gloves, etc.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSterilizing course automatic sterilization controlled by computer, easy to operate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"font-size: 0.875rem; display: inline !important;\"\u003eWith drying function, suitable dressing drying.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eWith over-temperature, over-pressure auto-protect device.\u003c\/li\u003e\n\u003cli\u003eThe door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can’t be start on if the doesn’t closed well.\u003c\/li\u003e\n\u003cli\u003eThe safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.\u003c\/li\u003e\n\u003cli\u003eThe power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.\u003c\/li\u003e\n\u003cli\u003eEquipped with a trolley\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 0.875rem;\"\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBrand:Sada Medical\u003cbr data-mce-fragment=\"1\"\u003eProduct Origin:China\u003cbr data-mce-fragment=\"1\"\u003eShipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAfter-sale Service: 1 year quality guarantee; Question responsed within 24 hours; Video or photos instruction guide.\u003c\/p\u003e\n\u003cp\u003eSpecifications:\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eModel technical data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003eTS-DDV100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eSterilizing chamber volume\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e90L(φ400×720mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eSterilizing plate\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e580*290*40mm（2 piece）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eWorking pressure\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eWorking temperature\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e134℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eAdjustment of temperature\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e105℃- 134℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eTime of sterilization\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e0-99 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eTime of drying\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e0-99 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eHeat average\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e≤± 2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e220V 50Hz  3.8-4KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eOuter size\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e940*690*1330mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003ePackage size\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e1030*770*1460mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"460\" data-mce-fragment=\"1\"\u003eN.W\/G.W\/\u003c\/td\u003e\n\u003ctd width=\"663\" data-mce-fragment=\"1\"\u003e187KG\/232KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" width=\"480x480\" height=\"480x480\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/RChGNM27JMw?si=4F2qErICvEainCUR\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-fragment=\"1\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers, dry ovens\u003cspan data-mce-fragment=\"1\"\u003e, consumables, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIf you're interested in our products, please feel free to contact us by\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eB\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":44414570135718,"sku":null,"price":10109.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Tabletopautoclave_3.jpg?v=1694665265"},{"product_id":"ha-bw-100l-150l-200l-300l-400l-new-arrival-horizontal-steam-sterilizer","title":"HA-BW Series Horizontal Cylindrical Pressure Steam Sterilizer – 100L to 400L HMI Touch Screen Autoclave for CSSD, Labs \u0026 Pharma","description":"\u003cdiv style=\"font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; line-height: 1.5; color: #2c3e4f; max-width: 100%;\"\u003e\n\u003c!-- Overview Section --\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eFor \u003cstrong\u003ehospital CSSD (Central Sterile Supply Department)\u003c\/strong\u003e, pharmaceutical cleanrooms, and large research labs that demand high‑throughput sterilization, the \u003cstrong\u003eSADA Medical HA-BW series horizontal cylindrical autoclave\u003c\/strong\u003e delivers industrial‑grade performance. With chamber capacities ranging from \u003cstrong\u003e100L to 400L\u003c\/strong\u003e, this \u003cstrong\u003ehorizontal pressure steam sterilizer\u003c\/strong\u003e features an HMI touch screen interface, jacket heating, optional pulse vacuum, and complete sterilization traceability (printer + FO value). Whether you need to process wrapped surgical packs, liquids, culture media, or medical waste, the HA‑BW ensures consistent, validated sterilization results. Built for 24\/7 operation in demanding environments, it’s the backbone of any modern \u003cstrong\u003einfection control equipment\u003c\/strong\u003e strategy.\u003c\/p\u003e\n\u003c!-- Video Embed Placeholder (replace with actual embed code) --\u003e\n\u003cdiv style=\"margin: 30px 0; padding: 20px; background: #fafcfd; border: 2px dashed #2c7da0; border-radius: 20px; text-align: center;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; color: #1e3a5f;\"\u003eProduct Video – HA-BW Horizontal Autoclave in Action\u003c\/h4\u003e\n\u003cp style=\"margin: 0 0 12px 0; font-size: 14px; color: #4a627a;\"\u003eWatch the HMI touch screen operation, door safety lock, and complete sterilization cycle.\u003c\/p\u003e\n\u003c!-- PASTE YOUR VIDEO EMBED CODE INSIDE THIS DIV --\u003e\n\u003cdiv style=\"background: #e9edf2; border-radius: 12px; padding: 40px 20px; color: #6c7e8f; font-size: 14px;\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/RPsgPP7y_ew\" title=\"How to operate a sterilizer?HA-BW Horizontal Steam Sterilizer–Fast, Reliable, and Safe Sterilization\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Key Features Grid (Enhanced) --\u003e\n\u003cdiv style=\"background: #f1f5f9; border-radius: 16px; padding: 20px; margin: 30px 0;\"\u003e\n\u003ch2 style=\"color: #1e3a5f; margin-top: 0; font-size: 22px; border-left: 4px solid #2c7da0; padding-left: 15px;\"\u003e⚙️ Why Large Healthcare Facilities Choose the HA‑BW Horizontal Autoclave\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; margin-top: 15px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📱 HMI Touch Screen + Microcomputer\u003c\/strong\u003e\u003cbr\u003eUser‑friendly interface with program selection (fabric, equipment, liquid, BD test, pressure test, custom).\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔄 Pulse Vacuum Option (HA‑BWV)\u003c\/strong\u003e\u003cbr\u003eRemoves air more effectively – ideal for wrapped instruments, porous loads, and textile packs.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📄 Complete Traceability\u003c\/strong\u003e\u003cbr\u003eBuilt‑in printer + FO value record + temperature\/time double guarantee – perfect for compliance.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🛡️ Multiple Safety Protections\u003c\/strong\u003e\u003cbr\u003eOver‑temperature, over‑pressure, door interlock, and safety valve – operator safe at all times.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔧 Jacketed Chamber + Drying\u003c\/strong\u003e\u003cbr\u003eHorizontal circular inner chamber with jacket structure – better temperature uniformity and drying performance.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e⚙️ Optimal Pipeline Design\u003c\/strong\u003e\u003cbr\u003eSUS304 piping, clamp structure for quick assembly – easy maintenance and hygienic.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Specifications – Two Tables --\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 30px 0 10px 0;\"\u003e📋 Technical Specifications – HA-BW Series (Standard, Without Pulse Vacuum)\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: white; border-radius: 16px; overflow: hidden; box-shadow: 0 1px 3px rgba(0,0,0,0.1);\"\u003e\n\u003cthead style=\"background: #1e3a5f; color: white;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eChamber Size (Ø×L mm)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eOverall Dimensions (L×W×H mm)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eSteam (KG)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eWater (KG)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003ePower (KW)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eNet Weight (KG)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BW100\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ420×750\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1160×650×1680\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤10\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤30\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑨\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BW150\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ472×880\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1290×690×1680\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤12\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤190\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑫\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BW200\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ472×1150\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1560×690×1680\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤13\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤190\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑫\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BW300\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ620×995\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1430×850×1760\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤18\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑮\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BW400\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ620×1320\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1755×850×1760\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤22\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑮\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 30px 0 10px 0;\"\u003e💨 HA-BWV Series (With Pulse Vacuum) – For Superior Air Removal \u0026amp; Wrapped Loads\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: white; border-radius: 16px; overflow: hidden; box-shadow: 0 1px 3px rgba(0,0,0,0.1);\"\u003e\n\u003cthead style=\"background: #1e3a5f; color: white;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eChamber Size (Ø×L mm)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eOverall Dimensions (mm)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eSteam (KG)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eWater (KG)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003ePower (KW)\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left;\"\u003eNet Weight (KG)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BWV100\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ420×750\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1160×650×1680\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤11\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤30\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑫\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BWV150\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ472×880\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1290×690×1680\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤13\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤190\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑮\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BWV200\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ472×1150\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1560×690×1680\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤15\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤190\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑮\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BWV300\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ620×995\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1430×850×1760\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤20\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑱\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px;\"\u003eHA-BWV400\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003eØ620×1320\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1755×850×1760\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤25\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e≤2+⑱\u003c\/td\u003e\n\u003ctd style=\"padding: 10px;\"\u003e510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef9e6; padding: 12px 18px; border-radius: 12px; margin: 10px 0;\"\u003e\n\u003cp style=\"margin: 4px 0;\"\u003e\u003cstrong\u003e🌟 Common Technical Parameters (All Models):\u003c\/strong\u003e Design pressure -0.1~0.3Mpa | Design temp 144°C | Working pressure 0.245Mpa | Working temp 105‑138°C | Vacuum -0.086Mpa | Temperature equilibrium ≤±2.0°C | Water pressure 0.1‑0.2Mpa | Compressed air 0.4‑0.7Mpa | Steam supply 0.3‑0.7Mpa | Power voltage: AC380V 50Hz three‑phase five‑wire.\u003cbr\u003e\u003cstrong\u003e🌟 Included Accessories:\u003c\/strong\u003e Drying device, printer, trays. Door: Safety lock electric lock + disc type embedded gear. Seals: Pneumatic or self‑expanding. Built‑in verification interface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications \u0026 Safety --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin: 35px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e🏥 Sterilization Applications (CSSD \/ Pharma \/ Labs)\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospital CSSD\u003c\/strong\u003e – wrapped \u0026amp; unwrapped surgical instruments, textile packs, gowns, drapes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical factories\u003c\/strong\u003e – fermentation equipment, production tooling, cleanroom garments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch labs\u003c\/strong\u003e – culture media, glassware, biohazardous waste\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDental \u0026amp; veterinary clinics\u003c\/strong\u003e – high‑volume instrument reprocessing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuneral homes \u0026amp; prosthetics fabrication\u003c\/strong\u003e – specialized load sterilization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e🛡️ Safety \u0026amp; Compliance Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eOver‑temperature \u0026amp; over‑pressure protection\u003c\/li\u003e\n\u003cli\u003eElectric door lock + safety interlock – cannot open under pressure\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eFO value \u0026amp; temperature\/time double guarantee\u003c\/li\u003e\n\u003cli\u003eStandard equipment verification interface (for validation)\u003c\/li\u003e\n\u003cli\u003eMultiple built‑in cycles: fabric, equipment, liquid, BD test, pressure test, custom\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Quality \u0026 Factory Introduction --\u003e\n\u003cdiv style=\"background: #f0f7f4; border-radius: 16px; padding: 20px; margin: 20px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e✅ Quality Management \u0026amp; Certifications\u003c\/h3\u003e\n\u003cp\u003eSADA Medical Co., Ltd. is certified under \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eEN ISO 13485:2016\u003c\/strong\u003e (Medical Devices). Each HA‑BW horizontal sterilizer is factory tested with cycle validation reports. Our workshop follows strict GMP guidelines. We have supplied \u003cstrong\u003elarge horizontal autoclaves, low‑temperature plasma sterilizers, and EO sterilizers\u003c\/strong\u003e to major hospitals and distributors worldwide. OEM configurations (double door pass‑through, custom trays, voltage, etc.) are available. 12‑month warranty, 24‑hour technical support, and spare parts supply.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e📄 Download the full catalog, user manual, and validation guide using the blue button below.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- CTA Button Block (WhatsApp prefill updated for HA-BW) --\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Get Your Quote \u0026amp; Expert Support in One Click\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eTalk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003c!-- WhatsApp button (prefill for HA-BW) --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BW%20horizontal%20steam%20sterilizer\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003c!-- Website inquiry button --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #343a40; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/contact\" target=\"_blank\"\u003e 🌐 Send Detailed Inquiry \u003c\/a\u003e \u003c!-- Catalog download button --\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6c7e8f; margin-top: 20px; text-align: center;\"\u003e✔ HS Code 8419200000 – Horizontal steam sterilizers for medical, surgical, and laboratory use.\u003cbr\u003e✔ 12‑month warranty, 24‑hour technical support.\u003cbr\u003e✔ Pulse vacuum (HA‑BWV) recommended for wrapped instruments and textile loads.\u003cbr\u003e✔ Double‑door (pass‑through) configuration available for cleanroom\/dirty side separation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"HA-BW150","offer_id":44464573579430,"sku":null,"price":4656.6,"currency_code":"USD","in_stock":true},{"title":"HA-BW200","offer_id":57473802633382,"sku":null,"price":5781.1,"currency_code":"USD","in_stock":true},{"title":"HA-BW300","offer_id":57473802666150,"sku":null,"price":6906.9,"currency_code":"USD","in_stock":true},{"title":"HA-BW400","offer_id":57473802698918,"sku":null,"price":8031.4,"currency_code":"USD","in_stock":true},{"title":"HA-BWV100","offer_id":57473802731686,"sku":null,"price":5305.3,"currency_code":"USD","in_stock":true},{"title":"HA-BWV150","offer_id":57473802764454,"sku":null,"price":5980.0,"currency_code":"USD","in_stock":true},{"title":"HA-BWV200","offer_id":57473802797222,"sku":null,"price":7105.8,"currency_code":"USD","in_stock":true},{"title":"HA-BWV300","offer_id":57473802829990,"sku":null,"price":8230.3,"currency_code":"USD","in_stock":true},{"title":"HA-BWV400","offer_id":57473802862758,"sku":null,"price":9356.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/HA-BW_Horizontal_Steam_Sterilizer_100-400L_Pressure_Autoclave_for_Hospital_CSSD-01_2.jpg?v=1779762957"},{"product_id":"mushroom-sterilization-sterilizer-autoclave-manufacturer","title":"Mushroom Sterilization Sterilizer Autoclave Manufacturer","description":"\u003cp\u003e\u003cstrong\u003eMushroom Sterilization Sterilizer Autoclave Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel: HA-BV\u003cbr\u003eSterilizing Volume: 250L-4000L\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHA-BV series pulsating vacuum sterilizers use saturated steam as the sterilizing medium, by relying on the physical property that the saturated steam can release a large amount of latent heat and moisture during condensation, it renders items to be sterilized in a highly heated and humid state. After a period of heat preservation, the purpose of sterilization is achieved. The effect of cold air on temperature is eliminated by means of pulsating vacuum exhaust, finally (he items drying is realized by the vacuum dehumidification combined with jacket.\u003c\/p\u003e\n\u003cp\u003eHA-BV series pulsating vacuum sterilizers are mainly used in central sterile supply department, third-party disinfecting supply centers, and operating rooms, where medical devices, dressings, rubber, lumen devices, implantable devices, and liquids are sterilized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of Horizontal Pressure Steam Sterilizer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBody of the Sterilizer：\u003c\/strong\u003e ◎ Designing, manufacturing and inspection are perfonned according to GB\/T150 “Pressure Vessel”, GB 8599 “Technical Requirements for Large Steam Sterilizer Automatic Control Type” and 1SG 21-2016 “Stationary l\u0026gt;ressure Vessel Safety Technical Supervision Regulations”. © The main structure is of a rectangular cross section with European ring-type jacket with reinforcing ribs. The doors are pneumatically sealed, and the two doors are interlocked, which fully meets the specific requirements.\u003c\/p\u003e\n\u003cp\u003e◎ The materials that come into contact with steam such as the interior liner and door panels are all S30408 stainless steel, with a designed service life up to 10 years and 20,000 sterilization cycles ( 316L stainless steel is the optional material with designed service life of 15 years and 30,000 sterilization cycles). The gear rack and the teech are made of S30408 stainless steel, and the jacket is made of high-quality Q245R material specific for pressure vessels, with S30408 optional.\u003c\/p\u003e\n\u003cp\u003e© With standard GMP authentication interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePiping System：\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e◎ 304 stainless steel sanitary pipes, with clamp joints. Adopting GEMU angle seat pneumatic valves imported from Germany, solenoid valves supplied by Taiwan AirTAC and directly connected water ring vacuum pump imported from German SPECK.\u003c\/p\u003e\n\u003cp\u003e◎ (Optional) Smart automatic drainage system, water-conservative noise reduction system and pipeline insulation treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cb\u003eControlling System：\u003c\/b\u003e\u003c\/strong\u003e ◎ Adopting imported Siemens PLC and colorful touch screens on the operator’ s side； the printer prints the process data of each stage in real time manner； with a variety of safety and alarming systems.\u003c\/p\u003e\n\u003cp\u003e◎ Equipped with a communication interface connected with the quality tracing system of the disinfecting supply center. Intelligent maintenance system, with remote monitoring and maintenance modules (optional).\u003c\/p\u003e\n\u003cp\u003e◎ Double pulsation processes more thoroughly remove the interior air, improving fatigue life of equipment, with excellent drying performance.\u003c\/p\u003e\n\u003cp\u003eSpecifications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"287\" colspan=\"2\"\u003eSize of Liner\u003c\/td\u003e\n\u003ctd width=\"114\"\u003eVolume\n\u003cp\u003e(m3)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"262\"\u003eOverall Size\n\u003cp\u003eLx Wx H(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"104\"\u003eWeight\n\u003cp\u003e(Kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"314\"\u003ec Steam.\n\u003cp\u003eConsumption : (Kg\/C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"305\"\u003eTap Water :\n\u003cp\u003eConsumption: (Kg\/C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"206\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd width=\"232\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003eWxH\n\u003cp\u003e(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"122\"\u003eDepth\n\u003cp\u003e(mm):\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV250\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e550 x 550\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e845\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e0.25\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e1136x1310x 1880\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e750\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e\u0026gt;8\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e120\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e2KW + 24KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV360\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e610×610\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1000\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e0.36\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e1320x 1350x 1930\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e850\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e22\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e180\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e2KW+ 30KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV600\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e610×910\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1150\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e0.6\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e1470x1410x2100\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e1250\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e35\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e320\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e3KW + 36KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV800\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e610×910\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1490\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e0.8\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e1820x1410x2100\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e1350\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e47\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e400\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e3.5KW + 48KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV1000\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e610×910\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1815\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e1.0\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e2250x1410x2100\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e1550\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e55\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e500\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e3.5KW + 54KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV1200\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e680×1180\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1490\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e1.2\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e1820x1490x2050\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e1650\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e65\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e600\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e3.5 KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV1500\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e680×1180\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1900\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e1.5\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e2220x1490x2050\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e1850\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e80\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e750\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e4KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV2000\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e900×1380\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e1650\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e2.0\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e1990x1860x2230\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e2300\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e106\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e1000\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e4.5KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV2500\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e900x 1380\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e2000\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e2.5\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e2360x1860x2230\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e2700\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e132\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e1250\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e6KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV3500\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e900×1380\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e2494\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e3.0\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e2830x1860x2230\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e3500\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e160\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e1500\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e8KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"204\"\u003eHA-BV4000\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e900×1380\u003c\/td\u003e\n\u003ctd width=\"122\"\u003e3250\u003c\/td\u003e\n\u003ctd width=\"114\"\u003e4.0\u003c\/td\u003e\n\u003ctd width=\"262\"\u003e3580x1860x2230\u003c\/td\u003e\n\u003ctd width=\"104\"\u003e4500\u003c\/td\u003e\n\u003ctd width=\"314\"\u003e215\u003c\/td\u003e\n\u003ctd width=\"305\"\u003e2000\u003c\/td\u003e\n\u003ctd width=\"206\"\u003e380V, 50HZ\u003c\/td\u003e\n\u003ctd width=\"232\"\u003e8KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eISO 9001:2015 Quality Management Systems\u003cbr\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" width=\"480x480\" height=\"480x480\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" width=\"480x480\" height=\"480x480\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"800L double door autoclave ready for delivery SADA MEDICAL\" src=\"https:\/\/www.youtube.com\/embed\/g4Ai9JRq5lU\" height=\"423\" width=\"752\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eIf you're interested in our products, please feel free to contact us by\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003cstrong\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003ch3\u003eFor more product information, please click the button below to download and view!\u003c\/h3\u003e\n\u003cdiv style=\"position: absolute; left: -93px; top: -19px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":44520610857126,"sku":null,"price":5500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/B_F0X_2F_0_J272_TE17.jpg?v=1698718647"},{"product_id":"ha-bv-series-horizontal-type-lifting-door-pulse-vacuum-autoclave","title":"HA-BV Series Horizontal type Lifting Door Pulse Vacuum Autoclave","description":"\u003cp\u003e\u003cstrong\u003eLifting Door Pulse Vacuum Autoclavee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel: HA-BV\u003cbr\u003eSterilizing Volume: 250L-800L\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHA-BV series pulsating vacuum sterilizer uses saturated steam as the sterilization medium, which would completely penetrate into the surface of the articles through pulsating vacuum, and all the microorganisms and their spores would be killed by it under high pressure. It is the most reliable and effective method in physical sterilization. Pulsating vacuum exhaust eliminates the influence of cold air on temperature, finally the sterilizing articles are dried by vacuum dehumidification combined with jacket.\u003c\/p\u003e\n\u003cp\u003eHA-BV series pulsating vacuum sterilizer can be widely used in pharmaceutical, bioengineering, medical health, scientific research and other fields. It is applied to sterilizing the articles with high grade requirements, such as sterile clothes, medical cages, tools, instruments, rubber, liquid, medical dressing and so on.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of Horizontal Pressure Steam Sterilizer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e◎ The Lifting door structure with removable-racks is motor chain driven with anli-pinch function, which guarantees more operation and installation space, is convenient for the loading and unloading for the articles.\u003c\/p\u003e\n\u003cp\u003e◎ The two lifting doors are with pressure safety interlock, the liquid program is specially with temperature safety interlock. The two doors are interlocked.\u003c\/p\u003e\n\u003cp\u003e© The inflation pressure drives the sealing ring to realize automatic sealing. The new high-quality high tear resistant silicone rubber circular hollow sealing ring has a special coating treatment on the surface, which is wear-resistant and smooth. It has better sealing effect and longer service life, with a service life of up to 1500 cycles.\u003c\/p\u003e\n\u003cp\u003e◎ The main rectangular structure is with European ring type jacket with reinforcing ribs. The sealing groove is directly welded on the annular jacket at both ends (Gctingc structure).\u003c\/p\u003e\n\u003cp\u003e◎ Control system： Siemens PLC and color touch screen, the whole process is automatically controlled by program, and the operating process status, temperature, pressure, time and other parameters are automatically displayed.\u003c\/p\u003e\n\u003cp\u003e◎ Traceability system： it has a communication interface connected with the quality traceability system of the disinfection supply center, and provides a software communication protocol connected with the traceability system.\u003c\/p\u003e\n\u003cp\u003e◎ It is equipped with sterilization procedures such as sterile clothes, tools and instruments, rubber, liquid, culture medium, waste and custom procedures, as well as BD test, vacuum leakage test and other test procedures.\u003c\/p\u003e\n\u003cp\u003e◎ The process data is printed in real time through the built-in micro needle printer, and a paperless recorder is equipped.\u003c\/p\u003e\n\u003cp\u003e◎ Intelligent maintenance system (optional)： Equipped with remote monitoring and maintenance module, which can realize remote monitoring and remote software upgrading of equipment operation.\u003c\/p\u003e\n\u003cp\u003e© Independent steam inlet design is optional for the customer, the steam would not pass through the jacket to avoid the pollution from the carton steel, and prevent the drying effected frm the jacket pressure drops.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e◎ \u003cstrong\u003e\u003cb\u003ePipeline system：\u003c\/b\u003e\u003c\/strong\u003e stainless steel sanitary pipeline with clamp joints, are all welded by automatic pipe welder. German GEMUE angle seat valve, Taiwan Airtac solenoid valve, German SPECK direct-connected water ring vacuum pump.\u003c\/p\u003e\n\u003cp\u003e◎ \u003cstrong\u003e\u003cb\u003eWater saving and noise reduction system (optional)：\u003c\/b\u003e\u003c\/strong\u003e Can reduce the circulating water consumption of vacuum pump by 30% and reduce the noise of vacuum pump.\u003c\/p\u003e\n\u003cp\u003e◎ \u003cstrong\u003e\u003cb\u003eAutomatic drain device (optional)：\u003c\/b\u003e\u003c\/strong\u003e Jacket automatic control drain device and inner chamber are equipped with automatic control drain device to automatically detect the temperature and pressure of jacket and inner chamber to drain automatically to ensure the saturation of steam.\u003c\/p\u003e\n\u003cp\u003e◎ With automatic drainage temperature regulation system, drainage temperature W 55 °C. ◎ Air filter： the filtration accuracy is W 0.22 jxm, and the sterilization rate reaches 99.97%.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Parameters and Utilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"464\"\u003e\n\u003cp\u003eDesigned Pressure of Inner Chamber\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"242\"\u003e\n\u003cp\u003e-0.1~0.3MPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"932\"\u003e\n\u003cp\u003eOpening Pressure for Inner Chamber's Safety Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"483\"\u003e\n\u003cp\u003e0.28MPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDesigned Pressure of Jacket\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.3MPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOpening Pressure for Jacket's Safety Valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.28MPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDesigned Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e150°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision of Sterilization Temperature Control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0~2°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum Working Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e139°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Uniformity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±0.5°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum Working Pressure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.25MPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNegative Pressure Pulsation Vacuum Amplitude and Times\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAmplitude -80~0KPa, Times 1~99\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eVacuum Leakage Rale\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤0.13KPa\/min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTimes of Pulses Across Pressure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAmplitude -80~80KPa, Times 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUltimate Vacuum\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-96KPa\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTimes of Positive Pressure Pulses\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1~3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/20231107112628_480x480.png?v=1699327631\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eISO 9001:2015 Quality Management Systems\u003cbr\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe title=\"Steam Autoclave for Pharmaceutical Industries - sadamedical.com\" src=\"https:\/\/www.youtube.com\/embed\/OD7KPjqwGQc\" height=\"560\" width=\"320\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eIf you're interested in our products, please feel free to contact us by\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003cstrong\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003ch3\u003eFor more product information, please click the button below to download and view!\u003c\/h3\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -93px; top: -19px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":44543080923302,"sku":null,"price":4500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/1_824f04d9-dd2e-41ca-844a-62780dbdd8ce.jpg?v=1699327745"},{"product_id":"pass-through-pressure-steam-sterilizer-with-motor-drive-doors","title":"Pass through pressure steam sterilizer with motor-drive doors","description":"\u003cp\u003e\u003cstrong\u003ePass through pressure steam sterilizer with motor-drive doors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel: MSG.B240H\/K\u003cbr\u003eSterilizing Volume: 240L, 360L, 600L, 800L, 1000L, 1200L, 1500L.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe large pressure steam sterilizer with motorized door series is suitable for sterilizing articles in supply rooms, pharmaceutical factories, laboratories and other places. It can sterilize high temperature, high pressure and high humidity resistant articles such as packaged and unpackaged articles, Class A hollow articles, Class B hollow articles and articles with internal pipes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of Horizontal Pressure Steam Sterilizer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1.The main controller adopts high-quality imported controller, which is accurate, stable and reliable.\u003cbr\u003e2.The human-computer interface adopts the 7-inch touch screen of 65000 color , which has powerful function and rich colors, and can display animation and curve report forms.\u003cbr\u003e3.The design of man-machine interface is beautiful and generous, and at the same time, it is more convenient for users to operate. It adopts the designs of menu program , one button touch operation and intensive operation.Each running process can be displayed in full color in real time. \u003cbr\u003e4.For the design of the controller software, a unique real-time feedback module based on the fuzzy control theory is realized to ensure the accuracy of the process. It can ensure the temperature band, the temperature fluctuation and the temperature uniformity of the equipment.\u003cbr\u003e5.A unique function of prompting maintenance information is designed to remind the users to maintain the equipment. It includes cleaning the sealing ring regularly, wiping the main body regularly and checking the filter regularly.\u003cbr\u003e6.Double sealed doors, relying on rack for pneumatic lifting, pneumatic sealing structure, easy to operate, safe and reliable.\u003cbr\u003e7.It adopts the imported high-quality solenoid valve. The performance is more stable and the service life is long.\u003cbr\u003e8.It has the perfect functions of prompting the fault information and self-diagnosing the faults.\u003cbr\u003e9.With a protective system of three-level user’s rights , it is convenient for the users to manage the equipment.\u003cbr\u003e10.It can be equipped with a bar code scanning device, which can be connected to the hospital HIS system easily.\u003cbr\u003e11.The USB storage system can be selected to store the running status of the equipment into the USB storage device in real time.\u003cbr\u003e12.The central monitoring system can be selected to realize the remote operation of the equipment.\u003c\/p\u003e\n\u003cp\u003eSpecifications:\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eThe main technical parameters\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe main technical parameters\u003cbr\u003e◇The design pressure of the main body: 0.4MPa          \u003cbr\u003e◇The maximum working pressure: 0.23MPa \u003cbr\u003e◇The design temperature: 150℃                 \u003cbr\u003e◇The maximum working temperature: 138℃      \u003cbr\u003e◇The selection of sterilization temperature: 105℃～138℃      \u003cbr\u003e◇Pressure when the safety valve is opened: 0.28MPa\u003cbr\u003e◇Pressure of steam source: 0.3MPa～0.5MPa      \u003cbr\u003e◇Requirements for water source: softened water with the pressure of 0.15-0.3Mpa\u003cbr\u003e◇The range of pulsation times is: 0～99 times          \u003cbr\u003e◇Range of sterilization time：0～9999S\u003cbr\u003e◇Drying time: 0～9999S  \u003c\/p\u003e\n\u003ctable cellspacing=\"0\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eCapacity\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"179\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eChamber size \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"17\"\u003e(W×D×H)mm\u003c\/span\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"202\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eOverall size\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e(mm)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"129\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eNet Weight \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"16\"\u003e(kg)\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\" width=\"262\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e(AC380V\/50Hz\/kW)\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMaximum steam consumption\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"17\"\u003e\u003cspan\u003e  \u003c\/span\u003e(Kg\/Cycle)\u003c\/span\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMaximum water consumption\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003eKg\/Cycle\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"179\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"202\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"129\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eBuild-in steam generator\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003eExternal steam supply\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e360L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e600*1000*600\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1255*1290*1900\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e930\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e22\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"15\"\u003e\/\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e200\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e360L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e600*1000*600\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1255*1230*1900\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e930\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e22\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e200\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e600L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e610*1180*910\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1325*1470*2320\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1400\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e39\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e280\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e600L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e610*1180*910\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1325*1470*2320\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1340\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/    \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e28\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e250\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e800L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e610*1460*910\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1325*1750*2320\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1500\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/    \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e30\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e250\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1000L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e610*1800*910\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1325*2090*1940\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1600\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/    \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e38\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e350\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG   D\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1200L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e680*1500*1180\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1410*1800*1940\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1950\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/  \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e4.5\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e40\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e360\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"130\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003eMSG.BJ\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"131\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1500L\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"179\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e680*1800*1180\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"202\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e1410*2090*1940\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"129\"\u003e\n\u003cp align=\"justify\" class=\"MsoNormal\"\u003e\u003cspan\u003e2200\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"131\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e\/    \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"130\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e4.5\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"215\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e45\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"251\"\u003e\n\u003cp align=\"center\" class=\"MsoNormal\"\u003e\u003cspan\u003e450\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ciframe width=\"752\" height=\"423\" src=\"https:\/\/www.youtube.com\/embed\/g4Ai9JRq5lU\" title=\"800L double door autoclave ready for delivery SADA MEDICAL\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers\u003cspan data-mce-fragment=\"1\"\u003e, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eIf you're interested in our products, please feel free to contact us by\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003cstrong\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -93px; top: -19px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":45663435980966,"sku":null,"price":9548.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/20240718120611.png?v=1721275592"},{"product_id":"new-arrival-fully-automatic-front-loading-horizontal-sterilizer","title":"New arrival fully automatic front loading horizontal sterilizer","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFully automatic front loading horizontal sterilizer \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel: MSG-B\u003cbr\u003eSterilizing Volume: 60L, 80L, 120L, 140L, 180L\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMSG series The full-automatic horizontal sterilizer is applicable to the sterlization of the articles from the depart-ments of the stomatology,the ophthalmology, the operating room, the laboratory and the other places.The full-automatic horizontal pulsating vacuum sterilizer can be used for the sterilization of theMSG.B serieshigh-temperature resistant and high-pressure resistant articles, such as the implantable instruments that are pack-aged, non-packaged, solid, Class A hollow,Class B hollow,and the instruments with the pipes inside.MSG.N series The full-automatic horizontal downdraft sterilizer(non-pulsating) can sterilize the exposed instru-ments,the packages of instruments, the packages of dressings,the rubber products,the liquids, the test instrumentsand the other articles resistant to the high temperature and the high pressure.\u003c\/p\u003e\n\u003cp\u003eShipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.\u003cbr\u003eLead Time：20 – 25 working days.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of Horizontal Pressure Steam Sterilizer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe control system adopts the PLC,and the man-machine interface adopts the color touch screen of 65 thousand.The whole system has powerful functions and high reliability.\u003c\/p\u003e\n\u003cp\u003eThe whole process,including water injection, pulsation (unique to the pulsating vacuum sterilizers), heatima, steril-ization and drying, runs automatically without manual supervision.\u003c\/p\u003e\n\u003cp\u003eThe touch screen can display the information of the status, the temperature, the pressure,the time anid thie “aultalarm in real time.\u003c\/p\u003e\n\u003cp\u003eEquipped with a micro printer, can record all of the information of the whole sterilization process.\u003c\/p\u003e\n\u003cp\u003eIt has the function of periodic counting. After the sterilization cycle is completed,there will be the text display on the touch screen and the buzzing prompts.\u003c\/p\u003e\n\u003cp\u003eMSG.B series The full automatic horizontal pulsating vacuum sterilizer has a built-in high-quality water ring pump,pulsating vacuum for 1-6 times, and the vacuum degree up to -0.09MPa (-0.9Bar),so to ensure the efficient removalof the air in the dressing and the disinfection bags and the gaps between the central control devices, in order toachieve the best vaporous saturation.\u003c\/p\u003e\n\u003cp\u003eMSG.B seriesThe full-automatic horizontal vacuum sterilizer adopts the internal circulation structure.and thewater ring pump does not need the external pipeline, which simplifies the installation requirements.MSG.B series The ful-automatic horizontal vacuum sterilizer has a unique program of pulsating vacuum drying.The residual humidity after drying does not exceed 0.2%.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe protective device for the heater:The system cuts off the power of the heater automatically and displays the alarm information,when the heater exceeds the set temperature\u003c\/p\u003e\n\u003cp\u003eThe alarm device for preventing dry-burning: The anti-dry burning device cuts off the power supply of the heater automatically and displays the alarm information,when the water level is lower than the heating pipe;\u003c\/p\u003e\n\u003cp\u003eThe door safety interlocking device (volume 80L):it uses an electronic door lock. The sterilizer can start the working procedure,only when the door is closed in place.The door lock is automatically closed and door can not be opened,when there is pressure in the cavity or the power supply is not turned on;\u003c\/p\u003e\n\u003cp\u003eThe door safety interlocking device (The volume\u0026gt; 120L):Only when the door is locked in place can the sterilizer start to work.The door safety interlocking device will be locked and the door can not be opened when there is pressure in the chamber;\u003c\/p\u003e\n\u003cp\u003eThe protective device for overtemperature and overpressure:The system alarms,the touch screen displays the alarm information and the program is interrupted automatically,when the temperature and the pressure inside the sterilization chamber exceed the safety range.Then the pressure is released and cooled to protect the articles to be sterilized from being damaged;\u003c\/p\u003e\n\u003cp\u003eThe safety valves for automatic pressure relief,when overpressure occurs:The safety valve is opened and the pressure is released,when the pressure in the sterilizing chamber exceeds the set pressure;\u003c\/p\u003e\n\u003cp\u003eThe protective measures for the electric power:The design has the protective function for short circuit and leakage to ensure the safety of the equipment and the person.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBrand:Sada Medical\u003cbr data-mce-fragment=\"1\"\u003eProduct Origin:China\u003cbr data-mce-fragment=\"1\"\u003eShipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAfter-sale Service: 1 year quality guarantee; Question responsed within 24 hours; Video or photos instruction guide.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications:\u003c\/p\u003e\n\u003cp\u003eDesign Pressure: 0.26mpa,  Design temperature: 150ºC\u003c\/p\u003e\n\u003cp\u003eMaximum working pressure: 0.23mpa,  The accuracy of temperature display: 0.1ºC\u003c\/p\u003e\n\u003cp\u003eSelection of sterilization temperature: 105-138ºC\u003c\/p\u003e\n\u003cp\u003eUniformity of temperature: ≤±0.5ºC\u003c\/p\u003e\n\u003cp\u003eMaterial of the cavity: SU304 stainless steel\u003c\/p\u003e\n\u003cp\u003eRequirements for water sources: Distilled water or purified water\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"71\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"59\"\u003eCapacity\u003c\/td\u003e\n\u003ctd width=\"88\"\u003eInner size(ΦxL)mm\u003c\/td\u003e\n\u003ctd width=\"98\"\u003eOverall dimension(L x W x H)mm\u003c\/td\u003e\n\u003ctd width=\"72\"\u003eNet Weight(kg)\u003c\/td\u003e\n\u003ctd width=\"54\"\u003eVoltage\u003c\/td\u003e\n\u003ctd width=\"70\"\u003eFrequency\u003c\/td\u003e\n\u003ctd width=\"53\"\u003epower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"71\"\u003eMSG-B60\u003c\/td\u003e\n\u003ctd width=\"59\"\u003e60L\u003c\/td\u003e\n\u003ctd width=\"88\"\u003e340X680\u003c\/td\u003e\n\u003ctd width=\"98\"\u003e780x480x1450\u003c\/td\u003e\n\u003ctd width=\"72\"\u003e175\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e220v\u003c\/td\u003e\n\u003ctd width=\"70\"\u003e50hz\u003c\/td\u003e\n\u003ctd width=\"53\"\u003e7.6kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"71\"\u003eMSG-B80\u003c\/td\u003e\n\u003ctd width=\"59\"\u003e80L\u003c\/td\u003e\n\u003ctd width=\"88\"\u003e370X755\u003c\/td\u003e\n\u003ctd width=\"98\"\u003e870x540x1450\u003c\/td\u003e\n\u003ctd width=\"72\"\u003e185\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e380v\u003c\/td\u003e\n\u003ctd width=\"70\"\u003e50hz\u003c\/td\u003e\n\u003ctd width=\"53\"\u003e7.6kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"71\"\u003eMSG-B120\u003c\/td\u003e\n\u003ctd width=\"59\"\u003e120L\u003c\/td\u003e\n\u003ctd width=\"88\"\u003e500×665\u003c\/td\u003e\n\u003ctd width=\"98\"\u003e880x650x1550\u003c\/td\u003e\n\u003ctd width=\"72\"\u003e252\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e380v\u003c\/td\u003e\n\u003ctd width=\"70\"\u003e50hz\u003c\/td\u003e\n\u003ctd width=\"53\"\u003e10.2kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"71\"\u003eMSG-B140\u003c\/td\u003e\n\u003ctd width=\"59\"\u003e140L\u003c\/td\u003e\n\u003ctd width=\"88\"\u003e500×765\u003c\/td\u003e\n\u003ctd width=\"98\"\u003e880x650x1550\u003c\/td\u003e\n\u003ctd width=\"72\"\u003e275\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e380v\u003c\/td\u003e\n\u003ctd width=\"70\"\u003e50hz\u003c\/td\u003e\n\u003ctd width=\"53\"\u003e10.2kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"71\"\u003eMSG-B180\u003c\/td\u003e\n\u003ctd width=\"59\"\u003e180L\u003c\/td\u003e\n\u003ctd width=\"88\"\u003e500×910\u003c\/td\u003e\n\u003ctd width=\"98\"\u003e1180x655x1550\u003c\/td\u003e\n\u003ctd width=\"72\"\u003e360\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e380v\u003c\/td\u003e\n\u003ctd width=\"70\"\u003e50hz\u003c\/td\u003e\n\u003ctd width=\"53\"\u003e10.5kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Quality Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eISO 9001:2015 Quality Management Systems\u003cbr data-mce-fragment=\"1\"\u003eEN ISO 13485:2016 Quality Management System - Medical Devices\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCERTIFICATES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C1_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/C2_480x480.png?v=1634710063\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSADA MEDICAL Workshop:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cimg height=\"480x480\" width=\"480x480\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Autoclave_Factory_480x480.jpg?v=1634693204\"\u003e\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eVideo of SADA MEDICAL Horizontal Autoclaves:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/UmsF8Fed3KY?si=7wlWx-09DNsCm9Aj\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCatalog, Brothures and User Manual Please refer below Link:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\"\u003ehttps:\/\/www.sadamedical.com\/pages\/catalog-download\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSada Medical\u003c\/strong\u003e\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis a professional supplier of steam autoclaves, low temperature plasma autoclaves, ethylene oxide sterilizers, dry ovens\u003cspan data-mce-fragment=\"1\"\u003e, consumables, we have exported to all over the world with affordable prices.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIf you're interested in our products, please feel free to contact us by\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eB\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eelow Contact Form\u003c\/strong\u003e\u003c\/span\u003e, looking foward to hearing from you soon.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":45663585173670,"sku":null,"price":7000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/Horizontalautoclave_2.jpg?v=1721282411"},{"product_id":"sd-m-series-horizontal-pulsating-vacuum-steam-sterilizer-100l-200l","title":"SD-M Series Horizontal Pulsating Vacuum Steam Sterilizer | 100L \/ 200L Hospital Autoclave","description":"Horizontal pulsating-vacuum steam sterilizer for hospital CSSD and professional healthcare applications. The SD-M Series is available in 100L and 200L configurations for project-specific sterilization capacity requirements.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRequest a quotation\u003c\/strong\u003e with your required capacity, configuration, quantity and destination.","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":46470060212390,"sku":"","price":10271.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/SADAMedicalSD-M100horizontalsteamsterilizerfrontview.png?v=1751276272"},{"product_id":"ha-bvs-ha-bvd-pulsed-vacuum-horizontal-steam-sterilizer-b-class-autoclave-for-clinics-labs","title":"HA-BVS\/HA-BVD Pulsed Vacuum Horizontal Steam Sterilizer | B-Class Autoclave for Clinics \u0026 Labs","description":"\u003cdiv style=\"font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; line-height: 1.5; color: #2c3e4f; max-width: 100%;\"\u003e\n\u003c!-- Overview Section --\u003e\n\u003cp style=\"font-size: 16px; margin-bottom: 20px;\"\u003eFor \u003cstrong\u003ehospitals, central sterile supply departments (CSSD), dental clinics, laboratories, and research centers\u003c\/strong\u003e that demand high‑efficiency B‑Class sterilization, the \u003cstrong\u003eSADA Medical HA-BVS (single door) and HA-BVD (double door) pulsed vacuum horizontal steam sterilizers\u003c\/strong\u003e deliver superior performance. These autoclaves use \u003cstrong\u003epulsed vacuum technology\u003c\/strong\u003e to remove air completely, ensuring uniform steam penetration and fast heating – ideal for \u003cstrong\u003esurgical instruments, medical textiles, liquids, glassware, and BD tests\u003c\/strong\u003e. The \u003cstrong\u003ePLC-controlled touchscreen HMI\u003c\/strong\u003e allows precise parameter monitoring, automated vacuum drying, and permanent sterilization record printing. Available in capacities from \u003cstrong\u003e150L to 1500L\u003c\/strong\u003e, with \u003cstrong\u003esingle or double door\u003c\/strong\u003e configurations, the HA‑BV series fits everything from small clinics to large hospital CSSD. Choose \u003cstrong\u003eHA-BVS (single door)\u003c\/strong\u003e for medium‑volume workflows or \u003cstrong\u003eHA-BVD (double door)\u003c\/strong\u003e for pass‑through, clean‑side\/dirty‑side separation in high‑volume operations.\u003c\/p\u003e\n\u003c!-- Video Embed Placeholder (replace with actual embed code) --\u003e\n\u003cdiv style=\"margin: 30px 0; padding: 20px; background: #fafcfd; border: 2px dashed #2c7da0; border-radius: 20px; text-align: center;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; color: #1e3a5f;\"\u003eProduct Video – HA-BVS\/HA-BVD Horizontal Sterilizer in Action\u003c\/h4\u003e\n\u003c!-- PASTE YOUR VIDEO EMBED CODE INSIDE THIS DIV --\u003e\n\u003cdiv style=\"background: #e9edf2; border-radius: 12px; padding: 40px 20px; color: #6c7e8f; font-size: 14px;\"\u003e\u003ciframe width=\"700\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/XY6QHzIEplQ\" title=\"HA-BVD 1000L Double Door Pulsed Vacuum Autoclave Shipped to Greece – Large Lab \u0026amp; Hospital Sterilizer\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Key Features Grid --\u003e\n\u003cdiv style=\"background: #f1f5f9; border-radius: 16px; padding: 20px; margin: 30px 0;\"\u003e\n\u003ch2 style=\"color: #1e3a5f; margin-top: 0; font-size: 22px; border-left: 4px solid #2c7da0; padding-left: 15px;\"\u003e⚙️ Why Healthcare Facilities Choose the HA‑BV Series\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; margin-top: 15px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🚪 Single or Double Door\u003c\/strong\u003e\u003cbr\u003eHA‑BVS (single door) for clinics\/labs; HA‑BVD (double door) for hospital pass‑through, clean\/dirty separation.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔄 Pulsed Vacuum Technology\u003c\/strong\u003e\u003cbr\u003eComplete air removal – ensures steam penetration into wrapped instruments, textiles, hollow loads, and liquids.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📱 PLC + Touchscreen HMI\u003c\/strong\u003e\u003cbr\u003eFully automatic control, real‑time monitoring, and data recording – includes printer for permanent sterilization records.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🌀 Automatic Vacuum Drying\u003c\/strong\u003e\u003cbr\u003eResidual moisture \u0026lt;0.2% – instruments and textiles come out dry, ready for storage or immediate use.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e📋 7 Sterilization Modes\u003c\/strong\u003e\u003cbr\u003eInstruments, fabrics, liquids, BD test, vacuum test, and custom programs – one machine for all loads.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🛡️ Multiple Safety Protections\u003c\/strong\u003e\u003cbr\u003eDoor interlocks (cannot open under pressure), over‑pressure safety valve, vacuum monitoring, low water protection.\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 180px; background: white; border-radius: 12px; padding: 12px 16px; box-shadow: 0 1px 2px rgba(0,0,0,0.05);\"\u003e\n\u003cstrong\u003e🔧 Durable Construction\u003c\/strong\u003e\u003cbr\u003eStainless steel chamber and optimized SUS304 piping – long‑term reliability, easy maintenance.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Specifications Table (150L-1500L) --\u003e\n\u003ch2 style=\"color: #1e3a5f; margin: 30px 0 10px 0;\"\u003e📋 Technical Specifications – HA‑BVS \/ HA‑BVD Series (150L – 1500L)\u003c\/h2\u003e\n\u003cp\u003eEngineered for high‑capacity B‑Class pulsed vacuum sterilization. Chamber and all piping are \u003cstrong\u003eSUS304 stainless steel\u003c\/strong\u003e. Below are the complete specifications for all models.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: white; border-radius: 16px; overflow: hidden; box-shadow: 0 1px 3px rgba(0,0,0,0.1);\"\u003e\n\u003cthead style=\"background: #1e3a5f; color: white;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eCapacity (L)\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eChamber Size (L×W×H mm)\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eExternal Size (L×W×H mm)\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eSteam (kg)\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eWater (kg)\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003ePower (kW)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)150\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e150L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e700×450×480\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e950×1120×1760\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤14\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤190\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e200L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e925×450×480\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1175×1120×1760\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤16\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤190\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)250\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e250L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e780×600×600\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1030×1300×1900\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤18\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)360\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e360L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1000×600×600\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1250×1300×1900\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤25\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)600\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e600L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1190×610×910\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1440×1310×1900\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤30\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤210\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)800\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e800L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1450×610×910\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1700×1310×1900\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤35\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)1000\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1000L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1250×680×1180\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1550×1440×1950\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤42\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)1200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1200L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1450×680×1180\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1700×1440×1950\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤50\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 8px;\"\u003eHA-BVD(S)1500\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1500L\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e1850×680×1180\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e2100×1440×1950\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤60\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e≤200\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e6.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef9e6; padding: 12px 18px; border-radius: 12px; margin: 10px 0;\"\u003e\n\u003cp style=\"margin: 4px 0;\"\u003e\u003cstrong\u003e🌟 B‑Class Pulsed Vacuum Advantage:\u003c\/strong\u003e Multiple pre‑vacuum pulses remove virtually all air from the chamber and load – ensuring complete steam penetration into wrapped packs, hollow instruments, porous textiles, and liquid loads. This meets the highest international standards for medical device sterilization.\u003cbr\u003e\u003cstrong\u003e🌟 Double‑Door (Pass‑Through) Configuration:\u003c\/strong\u003e HA‑BVD models allow loading on the dirty side and unloading on the clean side – essential for CSSD workflow compliance and preventing cross‑contamination.\u003cbr\u003e\u003cstrong\u003e🌟 7 Sterilization Modes:\u003c\/strong\u003e Instruments (wrapped\/unwrapped), fabrics\/textiles, liquids, BD test, vacuum test, and custom programs – flexible for all clinical and laboratory loads.\u003cbr\u003e\u003cstrong\u003e🌟 What's included:\u003c\/strong\u003e Horizontal sterilizer unit, PLC control panel with HMI touchscreen, printer, loading racks\/trolleys (as per capacity), user manual, and validation interface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Sterilization Modes \u0026 Applications --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin: 35px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e📋 7 Sterilization Modes\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrument Mode\u003c\/strong\u003e – Wrapped\/unwrapped surgical instruments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFabric\/Textile Mode\u003c\/strong\u003e – Gowns, drapes, surgical linens\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Mode\u003c\/strong\u003e – Culture media, solutions, pharmaceutical liquids\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBD Test Mode\u003c\/strong\u003e – Steam penetration validation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Test Mode\u003c\/strong\u003e – Chamber integrity verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Program 1 \u0026amp; 2\u003c\/strong\u003e – User‑defined parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px;\"\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003e🏥 Primary Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospital CSSD\u003c\/strong\u003e – Central Sterile Supply Department\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Rooms \u0026amp; Surgical Centers\u003c\/strong\u003e – High‑volume instruments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDental \u0026amp; Medical Clinics\u003c\/strong\u003e – Wrapped packs, textiles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical \u0026amp; Biotech Labs\u003c\/strong\u003e – Cleanroom equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch \u0026amp; University Laboratories\u003c\/strong\u003e – Glassware, media, waste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Door Type Decision Guide --\u003e\n\u003cdiv style=\"background: #e8f0fe; border-radius: 16px; padding: 20px; margin: 25px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e🚪 Single Door vs Double Door – Which One Do You Need?\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-top: 10px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 15px;\"\u003e\n\u003cdiv style=\"font-size: 24px; font-weight: bold; color: #2c7da0;\"\u003eHA-BVS (Single Door)\u003c\/div\u003e\n\u003cp style=\"margin: 8px 0 0 0; font-size: 14px;\"\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e Medium‑volume clinics, small laboratories, dental practices, research institutes.\u003cbr\u003eLoad and unload from the same side. Compact footprint. Ideal when space or workflow does not require pass‑through separation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; background: white; border-radius: 12px; padding: 15px;\"\u003e\n\u003cdiv style=\"font-size: 24px; font-weight: bold; color: #2c7da0;\"\u003eHA-BVD (Double Door)\u003c\/div\u003e\n\u003cp style=\"margin: 8px 0 0 0; font-size: 14px;\"\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e High‑volume hospital CSSD, large central sterile processing departments, pharmaceutical manufacturing.\u003cbr\u003eLoad contaminated instruments on one side, unload sterile packs on the other – eliminates cross‑contamination risk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Quality \u0026 Factory Introduction --\u003e\n\u003cdiv style=\"background: #f0f7f4; border-radius: 16px; padding: 20px; margin: 20px 0;\"\u003e\n\u003ch3 style=\"color: #1e3a5f; margin-top: 0;\"\u003e✅ SADA Medical – Quality \u0026amp; Certifications\u003c\/h3\u003e\n\u003cp\u003eSADA Medical Co., Ltd. is a professional manufacturer and supplier of \u003cstrong\u003ehorizontal autoclaves, steam sterilizers, low‑temperature plasma sterilizers, and washer disinfectors\u003c\/strong\u003e, exporting to over 80 countries worldwide. We are certified under \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eEN ISO 13485:2016\u003c\/strong\u003e (Medical Devices). The HA‑BV series \u003cstrong\u003epulsed vacuum horizontal sterilizer\u003c\/strong\u003e is factory‑tested with cycle validation reports. Each unit comes with a \u003cstrong\u003e12‑month warranty\u003c\/strong\u003e and \u003cstrong\u003e24‑hour technical support\u003c\/strong\u003e. A standard validation interface is included for IQ\/OQ\/PQ testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy customers trust SADA Medical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px; margin-top: 5px;\"\u003e\n\u003cli\u003eFactory‑direct pricing – no middleman markup\u003c\/li\u003e\n\u003cli\u003eOEM\/private labeling available for volume orders\u003c\/li\u003e\n\u003cli\u003e12‑month warranty + 24\/7 technical support\u003c\/li\u003e\n\u003cli\u003eFast worldwide shipping from Shanghai, Ningbo, Qingdao ports\u003c\/li\u003e\n\u003cli\u003eCustom configurations (trolleys, racks, voltage) available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e📄 Download the full catalog, user manual, and validation guide using the blue button below.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- CTA Button Block --\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; background: #f8f9fa; border-radius: 8px; text-align: center;\"\u003e\n\u003ch3 style=\"margin-bottom: 10px;\"\u003e📞 Upgrade Your Sterilization Process with HA‑BV Series\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 20px; font-size: 15px; color: #555;\"\u003eContact us for factory pricing, OEM service, and fast worldwide shipping. Talk directly to our sterilization specialists at \u003cstrong\u003eSada Medical Equipment Co., Ltd.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\"\u003e\n\u003ca style=\"display: inline-block; padding: 12px 24px; background: #25D366; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/wa.me\/8618056076519?text=Hi%20Sada%20Medical,%20I'm%20interested%20in%20the%20HA-BVS%20or%20HA-BVD%20pulsed%20vacuum%20horizontal%20sterilizer\" target=\"_blank\"\u003e 💬 WhatsApp Now \u003c\/a\u003e \u003ca style=\"display: inline-block; padding: 12px 24px; background: #007bff; color: #fff; text-decoration: none; border-radius: 6px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/www.sadamedical.com\/pages\/catalog-download\" target=\"_blank\"\u003e 📥 Download Full Catalog \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 16px; font-size: 14px; color: #666;\"\u003e📱 Tel \/ WhatsApp: +8615556517696   |   📧 amanda@sadamedical.com   |   🌍 sadamedical.com\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #6c7e8f; margin-top: 20px; text-align: center;\"\u003e✔ HS Code 8419200000 – Horizontal steam sterilizers for medical and laboratory use.\u003cbr\u003e✔ B‑Class pulsed vacuum – for wrapped instruments, textiles, hollow loads, and liquids.\u003cbr\u003e✔ 9 capacities from 150L to 1500L – single door (HA‑BVS) or double door (HA‑BVD).\u003cbr\u003e✔ PLC + HMI touchscreen – fully automatic with real‑time monitoring and printer.\u003cbr\u003e✔ Automatic vacuum drying – residual moisture \u0026lt;0.2%.\u003cbr\u003e✔ 7 sterilization modes – flexible for all clinical and lab loads.\u003cbr\u003e✔ Multiple safety protections – door interlocks, over‑pressure valve, vacuum monitoring.\u003cbr\u003e✔ Stainless steel chamber and optimized SUS304 piping.\u003cbr\u003e✔ 12‑month warranty, 24‑hour technical support.\u003cbr\u003e⚠️ Power supply: AC 380V three‑phase – please confirm your facility's power supply.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":56377131630758,"sku":null,"price":9553.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/B-ClassHorizontalAutoclavePLCTouchscreenControlPanel.jpg?v=1776052228"},{"product_id":"ha-bvs-ha-bvd-pulsed-vacuum-horizontal-steam-sterilizer-lift-door-b-class-autoclave","title":"HA-BVS \/ HA-BVD Pulsed Vacuum Horizontal Steam Sterilizer | B-Class Autoclave for Hospitals \u0026 CSSD","description":"For hospital central sterile supply departments (CSSD), operating rooms and professional healthcare facilities requiring high-capacity steam sterilization. SADA Medical provides B-Class pulsed-vacuum horizontal autoclave configurations with project-oriented quotation support.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRequest a quotation\u003c\/strong\u003e for chamber volume, door configuration, power requirements, quantity and destination.","brand":"Sada Medical","offers":[{"title":"Default Title","offer_id":56397550354598,"sku":null,"price":9550.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/files\/SadaMedicalLargeAutoclavePulseVacuumSterilizationEquipmentHa-Bvspictures_photos_3.jpg?v=1776667374"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/7759\/7350\/collections\/horizontal__autoclave.jpg?v=1634609165","url":"https:\/\/www.sadamedical.com\/collections\/horizontal-autoclave.oembed?page=2","provider":"Sada Medical","version":"1.0","type":"link"}